摘要
针对300 MW燃煤火电机组SCR脱硝系统出口NO
X
分布均匀性差
总排口与SCR出口NO
X
浓度偏差大等问题
对SCR系统喷氨格栅进行优化调整。调整结果表明
A/B两侧出口NO
X
浓度分布相对标准偏差从61.56%和69.57%下降至15.34%和21.84%。因此
喷氨优化对格栅式喷氨混合结构具有良好的调整效果
进而有效降低SCR氨逃逸水平
从而保证尾端设备的长期稳定运行。
Abstract
In this paper
SCR system is optimized and adjusted according to the problems of the low uniformity of outlet NO
X
concentrations and NO
x
large concentration deviation between the total discharge outlet and SCR outlet in 300 MW coal-fired power plant. The result shows that the relative standard deviations of NO
X
concentration distributions on both sides of A/B is reduced from 61. 56% to 15. 34% and from 69. 57% to 21. 84% respectively. Therefore
this optimization method has a good effect on the grid-spray ammonia mixing structure