High frequency harmonic detection of load on DC side converter valve of insulated overhead ground wire transmission in high-altitude environment
|更新时间:2026-07-17
|
High frequency harmonic detection of load on DC side converter valve of insulated overhead ground wire transmission in high-altitude environment
Vol. 63, Issue 7, (2026)
作者机构:
1. 中国南方电网有限责任公司超高压输电公司,广州,510620
2. 特变电工新疆新能源股份有限公司,西安,710000
作者简介:
基金信息:
DOI:
CLC:
Published:2026
稿件说明:
移动端阅览
LU Xiang, REN Chenglin, CHENG Zhouqiang, et al. High frequency harmonic detection of load on DC side converter valve of insulated overhead ground wire transmission in high-altitude environment[J]. 2026, 63(7).
DOI:
LU Xiang, REN Chenglin, CHENG Zhouqiang, et al. High frequency harmonic detection of load on DC side converter valve of insulated overhead ground wire transmission in high-altitude environment[J]. 2026, 63(7).DOI:
High frequency harmonic detection of load on DC side converter valve of insulated overhead ground wire transmission in high-altitude environment
The low air pressure at high altitude will reduce the space of the protective layer inside the converter valve equipment and reduce the current transmission capacity
so it is necessary to complete the switching action in a very short time to achieve the conversion between alternating current and direct current
while it will lead to the voltage and current change faster during operation
resulting in a variety of frequencies of harmonics. Then
the accuracy of harmonic detection is affected. The frequencies of these harmonics are usually distributed in higher frequency bands
and it is very difficult to extract their sequence. Therefore
a high frequency harmonic detection method of direct current side converter valve load in insulated overhead ground wires transmission in high-altitude environment is studied. The frequency harmonic current changes with time when the converter valve is loaded
and the transfer function of the load signal in the high frequency range is determined by the power flow theory to extract the frequency harmonic sequence of the converter valve load. According to the operating principle of low arm passive clamp
the instantaneous voltage of the converter valve load is determined
and the total number of bridge arm inputs is controlled to be a fixed value
achieving approximate modulation of the direct current side of insulated overhead ground wire transmission and correcting the squeezing interference caused by the instantaneous frequency of high-frequency harmonics. A window function is set to suppress the spectral leakage caused by the attenuation of high-frequency harmonics
convert the main lobe width to other high-frequency harmonics
and ultimately achieve full detection of high-frequency harmonics. After setting up a harmonic detection environment
it can be concluded through full detection of high-frequency harmonics that the designed harmonic detection method produces the smallest amplitude error and the best detection performance.
Research on prediction method of temperature distribution in thyristor of UHVDC converter valve
Research on closed loop control strategy of improved line voltage synthesis for multi-modular matrix converter
Design and performance study of composite power harvesting device for electric transmission lines based on triboelectric, piezoelectric and electromagnetic generator
Review of gas-insulated Transmission line (GIL) monitoring methods
Transmission line route planning based on multi-angle UAV laser point cloud fusion