In-situ test and numerical simulation of isolation of impact loads by open trenches
|更新时间:2026-06-25
|
In-situ test and numerical simulation of isolation of impact loads by open trenches
Vol. 35, Issue S1, (2014)
作者机构:
1. 郑州大学 交通运输工程系,郑州,450001
2. 宁波大学 土木工程系,浙江,宁波,315211
作者简介:
基金信息:
DOI:
CLC:TU435
Online First:20 June 2014,
Published:2014
稿件说明:
移动端阅览
XU Ping, ZHANG Tian-hang, SHI Ming-sheng, et al. In-situ test and numerical simulation of isolation of impact loads by open trenches[J]. 2014, 35(S1).
DOI:
XU Ping, ZHANG Tian-hang, SHI Ming-sheng, et al. In-situ test and numerical simulation of isolation of impact loads by open trenches[J]. 2014, 35(S1).DOI:
In-situ test and numerical simulation of isolation of impact loads by open trenches
the falling weight deflectometer (FWD)is adopted to replace the impact loads
and the vertical displaces in the near areas behind the trench are measured with the sensors of the FWD. The geotechnical parameters of the fields are in-door tested; the nonlinear dynamic finite element software of ABAQUS is adopted to establish a two-dimensional model
in which the far elements are defined as infinite to simulate the absorbing boundary; and so the vibration caused by wave bounces at the boundaries are avoided; and the FEM model is modified according to the in-situ tested vertical displacements. The vertical displacements of different conditions are simulated; the factors that influence the vibration isolation effects are analyzed; such as trench depth
trench width and distance between trench and impact loads. Some conclusions are drawn as follows. (1) The vibration isolation effects increase when the distance between trench and impact loads decrease; but in the actual vibration isolation engineering
the trench can not be constructed much near to the impact loads to guarantee the stability of the trench walls; so the distance between trench and impact loads should not be considered as an important factor in the vibration isolation design. (2) As to improve the vibration isolation effects
to increase the trench depth is much effective than the trench width
and a narrow and deep trench usually need much less excavation than a wide and shallow trench. (3) When designing the vibration isolation of normal civil and industrial buildings for impact loads
an open trench with 0.5-1.0 m width and 2.0-2.5 m depth is relatively reasonable by considering the isolation effects
excavation and maintenance fees; it is proved to be reasonable by comparing with one vibration isolation engineering.
Coupling mechanism of seepage and heat transfer in rock fracture based on physics-informed neural networks
Influence of construction gap on the force of steel lining in compressed air storage cavern
Stability and failure mode analysis of tunnel face in composite ground with upper sand and lower clay layers
Characterization method for the three-dimensional soil cutting failure surface based on damage energy dissipation
Pullout simulation on fully grouted rock bolts based on residual shear strength
Related Author
WANG Zhi-liang1
XIAO Zhi-huan1
SHEN Lin-fang1
LI Shao-Jun2
ZHANG Gui-min
SUN Wen-qing
ZHU Ze-fan
SU Yong-kang
Related Institution
Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology
State Key Laboratory of Geomechanics and Geotechnical Engineering Safety, Institute of Rock and Soil Mechanics, Chinese Academy of Sciences
School of Mechanics and Civil Engineering, China University of Mining and Technology
State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, China University of Mining and Technology