spalling of sealant and liner in the movement joint etc. of a metro station passageway have been found
which caused by excavation of adjacent deep foundation. In order to provide guidance for the metro security
the passageway accidents and damage cases have been described as follows: the project’s overview of the accident case is introduced including the design and engineering geology of the passageway and deep foundation; the main damage of the passageway is summarized detailedly; the main cause for the passageway’s damage is discussed based on circumstances surrounding
the passageway construction site
actual displacement data
pit monitoring data. Numerical simulations are carried out for the underground diaphragm wall and excavation construction of the foundation pit
prestressed anchorages are disturbed by the underground diaphragm wall construction and the computed passageway’s displacement is induced by drawdown. Finally
from the perspective of metro protections
the successful experience and accident protection lessons are summarized.