Model test of artificial ground freezing in shallow-buried rectangular cemented soil
|更新时间:2026-06-25
|
Model test of artificial ground freezing in shallow-buried rectangular cemented soil
Vol. 35, Issue S2, (2014)
作者机构:
1. 中国矿业大学(北京) 力学与建筑工程学院,北京,100083
2. 上海浦东新区市政工程建设管理中心,上海,211100
3. 中国矿业大学 力学与建筑工程学院,江苏,徐州,221116
作者简介:
基金信息:
DOI:
CLC:TU443
Online First:12 November 2014,
Published:2014
稿件说明:
移动端阅览
SHANG Hou-sheng, YUE Feng-tian, SHI Rong-jian. Model test of artificial ground freezing in shallow-buried rectangular cemented soil[J]. 2014, 35(S2).
DOI:
SHANG Hou-sheng, YUE Feng-tian, SHI Rong-jian. Model test of artificial ground freezing in shallow-buried rectangular cemented soil[J]. 2014, 35(S2).DOI:
Model test of artificial ground freezing in shallow-buried rectangular cemented soil
In order to obtain the temperature distribution and frost deformation law of frozen wall
the shallow-buried rectangular freezing engineering
which is a construction of the line 3 to cross line 6 in Guangzhou metro
was studied through the model test based on similarity theory. Conclusions are drawn as follows. Firstly
the temperature of the soil closed to the ground surface drops slowly under the influence of ground heat dissipation in shallow-buried freezing engineering .And the frozen wall closed to the ground surface is relatively weak. In the process of freezing
the average development speed of internal frozen wall is about 1.5 times that of the outward frozen wall. Secondly
small amount of frost heaving deformation is generated in the initial freezing stage. The freezing construction is proceeding with high-temperature brine; and the closed frozen wall is not formed at this stage. Thirdly
when the frozen wall is closed
the frost deformation of frozen wall increases obviously at the time of the freezing construction with low-temperature brine. In general
the soil frost heave deformation tends to decrease when the soil layer depth becomes smaller because the upper soil layer is compacted. There is significant interaction effect between the upper shallow covering and frozen wall in shallow-buried rectangular freezing engineering. This implies that the upper soil layer
which will produce deformation in the advance of the freezing process
will affect the temperature field distribution in frozen wall.
Model test on freezing reinforcement for shield junction Part 1: Distribution characteristics of temperature field in soil stratum during freezing process
Model test of horizontal freezing reinforcement in mud tank of slurry balanced shield
Model test on freezing reinforcement for shield junction in soft stratum (Part2): Frost heave effect of soft stratum during freezing process
Sealing system design and model testing of lining structures for artificial underground gas storage caverns in medium-hard rock strata
Calculation method of sliding surface stress based on segmented sliding surface stress measurement system
Related Author
SHI Rong-jian
YUE Feng-tian
ZHANG Yong
LU Lu
SHI Zhan
ZHANG Tie-jun
LI Mei-xiang
TAO Si-ji
Related Institution
State Key Laboratory for Geomechanics and Deep Underground Engineering, China University of Mining and Technology
School of Mechanics and Civil Engineering, China University of Mining and Technology
Changjiang Survey, Planning and Design Research Co., Ltd.
Nanjing Jiangning District Dike Reservoir Management