Research on effects of humidity on capillary migration of salt solutions in mural plaster
|更新时间:2026-06-25
|
Research on effects of humidity on capillary migration of salt solutions in mural plaster
Vol. 35, Issue 2, (2014)
作者机构:
1. 兰州大学 土木工程与力学学院西部灾害与环境力学教育部重点实验室,兰州,730000
2. 中国水电顾问集团西北勘测设计研究院,西安,710065
3. 兰州大学 西部环境教育部重点实验室,兰州,730000
作者简介:
基金信息:
DOI:
CLC:TU412
Online First:18 February 2014,
Published:2014
稿件说明:
移动端阅览
JIANG Xiao, ZHANG Hu-yuan, YAN Geng-sheng, et al. Research on effects of humidity on capillary migration of salt solutions in mural plaster[J]. 2014, 35(2).
DOI:
JIANG Xiao, ZHANG Hu-yuan, YAN Geng-sheng, et al. Research on effects of humidity on capillary migration of salt solutions in mural plaster[J]. 2014, 35(2).DOI:
Research on effects of humidity on capillary migration of salt solutions in mural plaster
Salt migration and enrichment caused by the capillary migration of the salt solutions have been the important cause of mural deterioration. The soluble salt redistribution which influenced by the capillary migration of salt solutions in mural plaster under different humidities is studied. At the same time
the increase in height of capillary with time
water content and electrical conductivity distribution with height
specimen surface before and after capillary saturation under different environmental humidities
either the content of the soluble solution distributions with height after capillary migration are analyzed. The test results show that
the lower the air relative humidity is
the more water migration to air during the capillary rise is; it is difficult for water to move upward at the same time. The water content of samples with height decreases
but the electrical conductivity of samples with height increases. The crystallization of soluble salt in rising capillary water occurred. NaCl crystallization is enriched in capillary striker
Na2SO4 crystallization is enriched mainly in the second striker. The results of this study can provide a scientific basis for preventing and controlling salt damage of the mural.