Field experimental study of transmitted characteristics of pile foundation under vertical load in loess slope
|更新时间:2026-06-25
|
Field experimental study of transmitted characteristics of pile foundation under vertical load in loess slope
Vol. 35, Issue 7, (2014)
作者机构:
1. 同济大学 地下建筑与工程系,上海,200092
2. 同济大学 岩土及地下工程教育部重点实验室,上海,200092
3. 厦门大学 土木工程系,福建,厦门,361005
作者简介:
基金信息:
DOI:
CLC:TU444
Online First:11 July 2014,
Published:2014
稿件说明:
移动端阅览
NIU Fu-sheng, XU Jian-cong, MA Kang. Field experimental study of transmitted characteristics of pile foundation under vertical load in loess slope[J]. 2014, 35(7).
DOI:
NIU Fu-sheng, XU Jian-cong, MA Kang. Field experimental study of transmitted characteristics of pile foundation under vertical load in loess slope[J]. 2014, 35(7).DOI:
Field experimental study of transmitted characteristics of pile foundation under vertical load in loess slope
Combined with the pile foundation engineering constructed in loess slope for supporting super bridge
field experiments on two neighboring piles at the same slope region are conducted to investigate transmitted characteristics as well as distribution feature of axial force
skin friction and lateral earth pressure of both upslope side and downslope side under different vertical load cases. The test results show that load transmitting of pile foundation can be obviously classified into 3 regions. The first region covers from pile head to about the depth of three times pile diameter; within this region
the axial force developed in pile upslope side is less than corresponding position at downslope side; moreover
its decrease extent with pile depth and work efficiency of skin friction are greater than pile downslope side. The second region is within about pile depth of three times to ten times pile diameter
which shows a less axial force decrease extent with pile depth in upslope side and higher work efficiency of skin friction along downslope side at the same elevation. The third region starts from the pile depth of about ten times pile diameter and ends with pile tip. For pile body in this region
the difference of axial force and skin friction for two sides at the same elevation are insignificant; and the load from super region could be even and well-distributed transmitted downwards. For the special issue of uneven earth pressure of pile foundation installed in loess slope
certain reduction in some degree for vertical bearing capacity of pile design is conducted; and some necessary revision of the calculation formula is made. The acquired study results can provide a reference for other similar pile foundation.
Field test and numerical simulation on thermo-mechanical response characteristics of a bridge energy row pile under heating-cooling cycles
Field test and numerical simulation of deformation characteristics of embankment on soft ground under different filling speeds
Comparative research on surrounding rock failure deformation and control mechanism in deep roadway driving along goaf based on discontinuous deformation analysis
Field test of piled beam-slab foundation
Fracture defusing mechanism and pressure characteristic tests of rapid setting cement-based grouts
Related Author
WU Di
CHEN Rong
KONG Gang-qiang
NIU Geng
MIAO Yu-song
WANG Zhen-xing
KONG Gang-qiang
ZHANG Chi
Related Institution
School of Science, Qingdao University of Technology
College of Civil and Transportation Engineering, Hohai University
The Development Construction Co. Ltd. of China Construction Eighth Engineering Division
Key Laboratory for Geomechanics and Embankment Engineering of Education Ministry , Hohai University
Research Center of Geotechnical and Structural Engineering, Shandong University