Reinforcement measures and deformation failure modes of subgrade on embedded reverse fault
|更新时间:2026-06-25
|
Reinforcement measures and deformation failure modes of subgrade on embedded reverse fault
Vol. 34, Issue 9, (2013)
作者机构:
1. 西南交通大学 土木工程学院,成都,610031
2. 云贵铁路云南段项目部,昆明,650000
作者简介:
基金信息:
DOI:
CLC:TU470
Online First:13 September 2013,
Published:2013
稿件说明:
移动端阅览
ZHANG Jian-jing, SI Chang-liang, ZHAO Yong-jun, et al. Reinforcement measures and deformation failure modes of subgrade on embedded reverse fault[J]. 2013, 34(9).
DOI:
ZHANG Jian-jing, SI Chang-liang, ZHAO Yong-jun, et al. Reinforcement measures and deformation failure modes of subgrade on embedded reverse fault[J]. 2013, 34(9).DOI:
Reinforcement measures and deformation failure modes of subgrade on embedded reverse fault
The experimental subgrade is used to model a high embankment in the Yunnan-Guizhou Railway
which has a bottom width of L=60 cm
top width of l=10 cm
and height of h=15 cm. The experiment models are used to study the effect of four ground stabilizing measures (called four groups) on responses of the high embankment under the action of a thrust fault ruptures. Group 1 is the case that no ground stabilizing measure is taken and is a basic test. The results from the other three groups are all compared with that from group 1. Group 2 is the case that a layer of geogrid is laid at the bottom of the embankment
Group 3 is that two layers of geogrids are laid at the middle and bottom of the embankment respectively
and Group 4 is that CFG pile is used to stabilize the ground and two layers of geogrids are laid at the bottom and middle of the embankment respectively. Several displacement gauges and dials are used to record embankment deformation. Deformation and failure modes by caused by different stabilization measures are analyzed. Results show that: (1) In the 4 models
embankment damage is mainly caused by the crack of 45° in embankment. (2) When fault displacement is equal to or less than 13.6% of the embankment height
the engineering measure with two layers of geogrids has the best efficiency for reducing damage; when the fault displacement is greater than 13.6% of the embankment height and less than or equal to 20.5% of the embankment height
the measure with both CFG piles and two layers of geogrids can achieve the best efficiency. (3) Due to part of energy absorbed by soil foundation
failure angle in the ground gradually reduces as engineering measure gradually strengthens
as a result embankment damage extent is reduced because the length affected increases. The conclusions in the paper have significance for engineering practice.
Numerical model and validation of failure mode for underground caverns in layered rock mass
Discussion on failure mechanism of retrogressive landslide and its reinforcement measures: taking a certain expressway retrogressive landslide for example
Study of bearing capacity of weightless foundation under local shear failure mode
Stability analysis of semi-circular breakwater on soft foundation under combined loading
Research on mechanical behaviors and failure modes of layer shale
Related Author
ZUO Shuang-ying
YE Ming-liang
TANG Xiao-ling
XU Jian-ke
SHI Wen-bing
SONG Dong-ri
REN Wei-zhongP
SHEN Bo
Related Institution
College of Resources and Environment Engineering, Guizhou University
State Key Laboratory of Geomechanics and Geotechnical Engineering, Institute of Rock and Soil Mechanics, Chinese Academy of Sciences
Highway Authority of Enshi Autonomous Prefecture
School of Civil and Hydraulic Engineering, Hefei University of Technology
State Key Laboratory of Hydraulic Engineering Simulation and Safety, Tianjin University