Review of soil liquefaction characteristics during major earthquakes in recent twenty years and liquefaction susceptibility criteria for soils
|更新时间:2026-06-25
|
Review of soil liquefaction characteristics during major earthquakes in recent twenty years and liquefaction susceptibility criteria for soils
Vol. 34, Issue 10, (2013)
作者机构:
1. 南京工业大学 岩土工程研究所,南京,210009
2. 江苏省土木工程防震技术研究中心,南京,210009
3. 环境保护部核与辐射安全中心,北京,100082
4. 中国地震局地球物理研究所,北京,100081
作者简介:
基金信息:
DOI:
CLC:TU441+.2
Online First:18 October 2013,
Published:2013
稿件说明:
移动端阅览
CHEN Guo-xing, JIN Dan-dan, CHANG Xiang-dong, et al. Review of soil liquefaction characteristics during major earthquakes in recent twenty years and liquefaction susceptibility criteria for soils[J]. 2013, 34(10).
DOI:
CHEN Guo-xing, JIN Dan-dan, CHANG Xiang-dong, et al. Review of soil liquefaction characteristics during major earthquakes in recent twenty years and liquefaction susceptibility criteria for soils[J]. 2013, 34(10).DOI:
Review of soil liquefaction characteristics during major earthquakes in recent twenty years and liquefaction susceptibility criteria for soils
This paper reviews the characteristics of soil liquefaction-induced damage observed from the Northridge
USA earthquake
1994
the Hanshin
Japan earthquake
1995
the Kocaeli
Turkey earthquake
1999
the Chi-Chi
Taiwan earthquake
1999
in China
the Wenchuan
China earthquake
2008
the Maule
Chile Earthquake
2010
the Darfield and Christchurch
New Zealand earthquake
2010 to 2011
and the great East Japan earthquake
2011. There are several characteristics in the occurrence of liquefaction and consequence damage which are different from a number of cases experienced in these earthquakes. These are summed up as follows: (1) The unprecedented long duration of the shaking and extensive makes the occurrence of liquefaction in the newly reclaimed land
fill area is 300~400 km distant from the epicentral area attributed to the rarely encountered huge moment magnitude Mw9.0 earthquake. (2) A number of site liquefactions and lateral spreadings are observed in seismic intensity scales of Ⅴ and Ⅵ
an area of low intensity is attributed to the encountered magnitude scale Ms8.0 and Mw8.8 earthquakes. (3) Severe liquefactions in sites are observed having young alluvial
lacustrine deposits along rivers and sea bay areas
and in reclaimed land
fill area contains fine-grained soils
gravel sands in less than fifty years. (4) Severe liquefaction in natural gravel sand deposits occurs. (5) Soil liquefies in depth of 20 m. (6) Liquefaction and re-liquefaction of the sites over a large region do not result in densification of the loose deposit
future earthquakes of sufficient magnitude can again induce liquefaction. (7) Severe liquefaction occurs in low to moderate plasticity soils containing more than 50% fines content (grain size is
smaller than 0.075 mm) or more than 25% of clay content (grain size is
smaller than 0.005mm)
however
field evidence of liquefaction may not be observed in transition behavior fine-grained soils between sand-like and clay-like behaviors. (8) Ground cracking without venting of sand boils is more likely as the depth and thickness of the liquefied layer increases and decreases
respectively; vented material
provided field evidence of liquefaction
may be absent due to the large depth to
and small thickness of
the liquefied layers. There are a number of spectacular case histories of liquefaction of sediments deposited in late Pleistocene time Q3. The clay content is not a reliable index for evaluating between clay-like and sand-like behaviors in a fine-grained soil. Fine-grained soils with the low plasticity index PI and high water content wc are susceptible to liquefaction; the use of the PI and water content to liquid limit ratio wc/LL is a good criterion of liquefaction possibility; for soils. Based on work in progress of the case histories of liquefaction and the results of laboratory tests for fine-grained soils from Boulanger
Idriss
Bray and Sancio
Seed and Cetin et al
a new liquefaction possibility criterion for soils is proposed as follows: soils with PI<12 and wc/LL>0.85 are susceptible to liquefaction; soils with 1220 or wc/LL<0.80 is not susceptible to liquefaction.