Study of consolidation theory of composite ground with granular columns under nonuniform distribution of initial excess pore water pressure
|更新时间:2026-06-25
|
Study of consolidation theory of composite ground with granular columns under nonuniform distribution of initial excess pore water pressure
Vol. 32, Issue 9, (2011)
作者机构:
1. 中原工学院 建筑工程学院,郑州,450007
2. 中原工学院 现代教育技术中心,郑州,450007
3. 浙江大学 岩土工程研究所,杭州,310027
作者简介:
基金信息:
DOI:
CLC:TU43
Online First:13 September 2011,
Published:2011
稿件说明:
移动端阅览
ZHANG Yu-guo, YUE Feng, XIE Kang-he. Study of consolidation theory of composite ground with granular columns under nonuniform distribution of initial excess pore water pressure[J]. 2011, 32(9).
DOI:
ZHANG Yu-guo, YUE Feng, XIE Kang-he. Study of consolidation theory of composite ground with granular columns under nonuniform distribution of initial excess pore water pressure[J]. 2011, 32(9).DOI:
Study of consolidation theory of composite ground with granular columns under nonuniform distribution of initial excess pore water pressure
Aiming at the shortcoming of the existing consolidation theories of composite ground without considering nonuniform distribution of initial excess pore water pressure in practical engineering
the consolidation theory of composite ground with granular columns is studied in-depth by analytical method; and a general analytical solution is given to the consolidation problem for the composite ground with granular columns under nonuniform distribution of initial excess pore water pressure. The three special cases for nonuniform distribution of initial excess pore water pressure are discussed; and the expressions of average excess pore pressure and average degree of consolidation are derived under the rectangular (uniform)
triangle and inverted triangle distribution of initial excess pore pressures. The results show that the distribution of initial excess pore water pressures has obvious influence on the consolidation of the composite ground with single drainage boundary. Under the uniform and triangle distribution of initial excess pore pressure
the excess pore water pressure dissipates gradually with the increase of Tv
and the one is always maximal at the bottom of foundation during consolidation; under the inverted triangle and trapezoidal ( pB /pT =0.5) distribution of the initial pore water pressure
the Tv value is bigger
the excess pore water pressure isochrones are gentler
and the position of maximal excess pore pressure shifts from the top of foundation to the bottom; the change of excess pore water pressure reflects the characteristic “from small to big