Reliability analysis of wet-sprayed fiber reinforced concrete lining structure within soft and weak rock mass using response surface method
|更新时间:2026-06-25
|
Reliability analysis of wet-sprayed fiber reinforced concrete lining structure within soft and weak rock mass using response surface method
Vol. 29, Issue S1, (2008)
作者机构:
1. 江南大学 环境与土木工程学院,无锡,214122
2. 中铁19局集团第5工程有限公司,大连,116000
作者简介:
基金信息:
DOI:
CLC:U459
Online First:15 April 2016,
Published:2008
稿件说明:
移动端阅览
HUA Yuan, ZHOU Tai-quan, Lü Bao-hua. Reliability analysis of wet-sprayed fiber reinforced concrete lining structure within soft and weak rock mass using response surface method[J]. 2008, 29(S1).
DOI:
HUA Yuan, ZHOU Tai-quan, Lü Bao-hua. Reliability analysis of wet-sprayed fiber reinforced concrete lining structure within soft and weak rock mass using response surface method[J]. 2008, 29(S1).DOI:
Reliability analysis of wet-sprayed fiber reinforced concrete lining structure within soft and weak rock mass using response surface method
Due to the diversity of the wet-sprayed fiber reinforced concrete lining structure physico-mechanical parameters and the difficulty of the explicit expression of limit state failure function for concrete strength
the reliability analysis for the wet-sprayed concrete lining structure is difficult to perform. The response surface method is proposed to calculate the reliability of the wet-sprayed concrete lining structure. The calculation process is given.In the determination calculation of the rockmass and tunnel lining structure
the nonlinear finite element method is used while the second order response method is used in the reliability analysis. As a case study
the wet-sprayed fiber reinforced concrete tunnel lining structure for Ganzhou-Longyan Jinhuashan Railway tunnel in soft and weak rockmass
the reliability analysis for the tunnel lining structure is performed using the method proposed. The numerical analysis result shows that the reliability index for the wet-sprayed concrete tunnel lining structure is higher and the tunnel lining structure is in safe state.