The settlement and uneven settlement are the key problems subjected to the design theory for tier buildings on deep soft ground. Taking an important project in Wenzhou City as background
the application of the composite foundation of pre-cast tubular pile and mixing cement pile was introduced. Based on the in-site loading test
the major engineering characteristic of this type of composite foundation was studied. Settlement
the stress ratios and load ratios of piles to soil were analyzed carefully. The results show that the stress ratios of tubular piles to cement mix pile and the stress ratios of piles to soil vary little during the load testing
the bearing capacities of soil can exploit quite fully. It will be provided as references for future design and research.