Comprehensive optimal load configuration method for misalignment tolerance of wireless charging system
|更新时间:2026-06-04
|
Comprehensive optimal load configuration method for misalignment tolerance of wireless charging system
Vol. 45, Issue 6, (2026)
作者机构:
1. 中国电力科学研究院有限公司,北京,100192
2. 先进输电技术全国重点实验室,北京,102209
作者简介:
基金信息:
DOI:
CLC:TM724
Published:2026
稿件说明:
移动端阅览
YANG Fuyao, SUN Hao, LIU Yang, et al. Comprehensive optimal load configuration method for misalignment tolerance of wireless charging system[J]. 2026, 45(6).
DOI:
YANG Fuyao, SUN Hao, LIU Yang, et al. Comprehensive optimal load configuration method for misalignment tolerance of wireless charging system[J]. 2026, 45(6).DOI:
Comprehensive optimal load configuration method for misalignment tolerance of wireless charging system
Power level improvement is an important trend of wireless charging system (WCS) for electric vehicles. To improve the power level considering the misalignment tolerance of WCSs
a high-power WCS prototype with S-S topology is proposed based on the comprehensive optimal load configuration method. Firstly
the power and efficiency characteristics of S-S and LCC-LCC topology WCSs are compared in the unified circuit by equivalent conversion of the compensation topology
and the advantages of the traditional S-S topology for high-power WCS are evaluated by considering the cost
power density and reliability
etc. Meanwhile
a comprehensive optimal load configuration method that accounts for the statistical characteristics of the parking position is proposed
and the finite element method is used to calculate the efficiency characteristics under different load conditions. The results show that the proposed method achieves the highest expected efficiency
modestly improves the average efficiency
and mitigates the efficiency degradation resulting from the misalignment. Finally
a 22 kW S-S topology WCS prototype is designed and manufactured for experimental validation. The results show that
with the proposed comprehensive optimal load configuration method
the magnetic coupler efficiency of the WCS prototype is around 95% under different misalignment conditions. With 200 mm lateral misalignment
the efficiency of the prototype is 94.688%
only 0.464% lower than that under alignment condition. These results verify the effectiveness of the proposed method in enhancing misalignment tolerance. The achievement of this study can provide a theoretical basis for the misalignment tolerance improvement of high-power WCSs.