new device-control grid was introduced into the powder electrostatic-eliminator to improve the efficiency of electrostatic elimination. The control grid was a cylindrical metal foil
pasted in the pipe wall of PVC. The efficiency of electrostatic elimination was improved by controlling the polarity of the grid voltage. Ways of designing an intelligent powder electrostatic-eliminator are presented.
关键词
Keywords
references
Martin Glor. Ignition source static electricity: incident investigation[J]. Journal of Electrostatics, 2009,67:242-246.
Gajewski A. Multichannel measurement of ESD[J]. Journal of Electrostatics, 2009,67:271-274.
Berta I. Use of soft computing methods in risk assessment of electrostatic fire and explosion hazards in industries[J]. Journal of Electrostatics, 2009,67:235-241.
Wang Dong-yan. Hazards and control countermeasures in China[C]∥Proceedings of the 6th international colloquium on dust explosions. Shenyang : Northeastern University Press, 1994,1.