Research on online measurement technology of dual-redundant all-fiber optical current sensors
|更新时间:2026-05-21
|
Research on online measurement technology of dual-redundant all-fiber optical current sensors
Vol. 63, Issue 5, (2026)
作者机构:
1. 国网江苏省电力有限公司电力科学研究院
2. 北京世维通光智能科技有限公司
作者简介:
基金信息:
DOI:
CLC:
Published:2026
稿件说明:
移动端阅览
PANG Fubin, CHEN Shi, WANG Qianglong, et al. Research on online measurement technology of dual-redundant all-fiber optical current sensors[J]. 2026, 63(5).
DOI:
PANG Fubin, CHEN Shi, WANG Qianglong, et al. Research on online measurement technology of dual-redundant all-fiber optical current sensors[J]. 2026, 63(5).DOI:
Research on online measurement technology of dual-redundant all-fiber optical current sensors
In response to the performance degradation problem of semiconductor light sources and photodetectors in all-fiber optical current sensors during long-term operation with charge
this paper proposes an online measurement technology based on dual redundancy configuration. Firstly
the optical path scheme and working principle of the dual redundant sensor were introduced; Then
by establishing a dual band optical model
the modulation and demodulation measurement scheme of the sensor was explored
and the current demodulation error and temperature influence error of the sensor were simulated and analyzed; Finally
a sensor prototype was built
and nonlinear and temperature error tests were conducted on the sensor prototype. A real-time monitoring method was proposed to verify the accuracy of the sensor
and the effects of magnetic field interference and vibration interference were studied. The results show that within 5%Ir~ 120%Ir(Ir=500A)
the prototype measurement error is less than ±1%; Within the range of -40℃ to +80℃
the measurement error is less than ±0.1%
and accurate self-monitoring with the measurement error of less than ±0.2% is achieved; Under the influence of magnetic field interference and vibration interference
the measurement error is also less than ±0.2%. The developed dual redundant all-fiber optical current sensor has achieved practical measurement accuracy requirements.