In order to accurately study the heat transfer problem of the coolant flow in the engine water jacket
a gas liquid two phase flow model suitable for the boiling heat transfer in the engine water jacket was established on the basis of the mixture multiphase flow model. The temperature of the fourth cylinders fire surface was measured by a certain four cylinder gasoline engine
and the high accuracy of the two phase flow simulation was verified compared with the traditional single phase flow simulation. On this basis
the high temperature danger zone of the water jacket wall was found out
and the optimization scheme was proposed according to the design requirements of the engine water jacket. Results show that after optimization
the coolant flow and cooling are more uniform
the wall temperature of the water jacket is decreased and the heat transfer effect is also improved
which provides a reference for the future research on engine boiling heat transfer and the design of cooling water jacket.