[Objective] In position servo applications of interior permanent magnet synchronous motor (IPMSM)
accurate detection of the rotor’s initial position is essential for ensuring absolute position control precision. However
traditional sensorless control algorithms commonly face two limitations: the starting position is constrained to specific points
and mechanical angle deviation occurs during the pre-positioning process. [Methods] To address these issues
an initial mechanical angle identification strategy without pre-positioning was proposed for IPMSM. Firstly
the inductance mathematical model of the self-sensing topology IPMSM was established
and the mechanical fundamental frequency characteristics of the self-sensing IPMSM inductance were analyzed. Secondly
the mathematical model of high-frequency response current after line-to-line injection was derived
and the initial mechanical angle of the rotor was detected by utilizing the correlation between the high-frequency response current and the rotor’s initial mechanical angle. Finally
the proposed strategy was verified on a self-sensing IPMSM test platform. [Results] The experimental results demonstrated that
compared with the conventional strategy
the proposed control strategy achieved arbitrary position identification across four sectors without requiring multiple pre-positioning steps. [Conclusion] The proposed solution addresses the starting and pre-positioning travel limitations of traditional methods
providing a superior approach for pre-positioning-free startup of IPMSM.