梁喆. Energy Efficiency Test and Energy-saving Analysis of Once-through Boiler[J]. 2013, (1): 92-95.DOI:
Energy Efficiency Test and Energy-saving Analysis of Once-through Boiler
摘要
对15台同型号贯流式蒸汽锅炉进行能效测试。测试用锅炉主要热损失为排烟热损失
占到总损失的85%以上。对比TSG G0002——2010中对锅炉设计参数的要求
分析了锅炉热损失产生的原因及节能方法
以指导锅炉节能运行和节能改造。
Abstract
The thermal efficiency of 15 once-through boilers of the same model was tested. The waste heat loss was the main heat loss in tested boilers
which occupied over 85% . By comparing with the demand of design parameters in TSG G0002-2010
the causes of heat loss and energy-saving measures were discussed. It provided guidance on boiler’s energy-saving operation and energy-saving reconstruction.