1. 新余钢铁集团有限公司第一动力厂
2. 新余钢铁集团机动能源处
Published:2012
移动端阅览
[1]黄素云,王军,梁云,黄静.威金斯转炉煤气柜日常运行中的故障与处理[J].能源研究与管理,2012(04):97-99+104.
黄素云, 王军, 梁云, et al. Faults and Solutions in the Daily Use of Wiggins Gas Converting Cabinet[J]. 2012, (4): 97-99+104.
[1]黄素云,王军,梁云,黄静.威金斯转炉煤气柜日常运行中的故障与处理[J].能源研究与管理,2012(04):97-99+104. DOI:
黄素云, 王军, 梁云, et al. Faults and Solutions in the Daily Use of Wiggins Gas Converting Cabinet[J]. 2012, (4): 97-99+104. DOI:
某厂2座8万、12万m3威金斯柜在运行中出现了氧含量超标、漏气、钢丝绳断裂、柜容指示不准、活塞倾斜度测量不准等故障
通过技术改造、加强对设备的日常维护和检查、完善操作工艺等措施
取得了一定的效果
保障了气柜的可靠运行。
Some group has two Wiggins 2 gas converting cabinet of 8 000 cubic meters and 12 0000 cubic meters which have oxygen content extended
leaking problem
wire rope fracture
capacity indicating faults
and piston measurements mistakes of inclination.But through technological revolution
strengthening on daily maintenance and device checking
together with perfect operation system
effective results have been found already.It brought reliable guarantee on the machine’s mouthy run in daily work.
0
Views
51
下载量
1
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution