阳璐, 吕浩军. Discussion of 600 MW Coal-fired Unit Cold Start Scheme without Motor Pump[J]. 2013, (1): 55-58.DOI:
Discussion of 600 MW Coal-fired Unit Cold Start Scheme without Motor Pump
摘要
为了提高火电厂运行经济性和机组可用率
通过对600MW强制循环炉燃煤机组无电泵启动方案的可行性分析
阐述了无电泵情况下
实现机组整套启动具体步骤及注意事项
为同类系统布置的其它电站机组类似情况下的整组启动提供借鉴。
Abstract
In order to improve the economic efficiency of the thermal power plant operation and availability of the unit
feasibility of the scheme that 600 MW forced circulation furnace coal-fired unit start without motor pump was analyzed. And the specific steps and precautions without electric pump to realize the units start was discussed. It is provided reference for unit start-up of the other power plant units which has similar system layout.