1. 赣能股份有限公司江西丰城二期发电厂
2. 江西省科学院能源研究所
3. 江西江联能源环保股份有限公司
Published:2012
移动端阅览
[1]匡仁钦,万斌,佘宏飞.容克式空预器单侧停运改进措施[J].能源研究与管理,2012(02):37-38+47.
匡仁钦, 万斌, 佘宏飞. Remedial Measures of One-side Ljungotroem Air Heaters Shut Downs[J]. 2012, (2): 37-38+47.
[1]匡仁钦,万斌,佘宏飞.容克式空预器单侧停运改进措施[J].能源研究与管理,2012(02):37-38+47. DOI:
匡仁钦, 万斌, 佘宏飞. Remedial Measures of One-side Ljungotroem Air Heaters Shut Downs[J]. 2012, (2): 37-38+47. DOI:
通过分析700MW机组运行时单侧空预器停运消缺操作方案
提出了转子回转式空气预热器出现的常见问题
分析了原因
介绍了几种有效的改进措施
使机组在运行中进行单侧空预器消缺时显著提高机组运行的安全性。
The operation of one-side ljungotroem air heaters shut downs in 700 MW unit was analyzed
problems of rotary air preheaters were described
and their origin was analyzed.Some suggestions for improvement were introduced
and the security and efficiency of operation were increased greatly.
0
Views
43
下载量
1
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution