江西赣能股份丰城二期发电厂
Published:2012
移动端阅览
[1]曾名劭.700MW机组锅炉配煤掺烧优化试验[J].能源研究与管理,2012(02):23-26.
曾名劭. Optimization Test of 700MW Unit Boiler with Blended Coals[J]. 2012, (2): 23-26.
[1]曾名劭.700MW机组锅炉配煤掺烧优化试验[J].能源研究与管理,2012(02):23-26. DOI:
曾名劭. Optimization Test of 700MW Unit Boiler with Blended Coals[J]. 2012, (2): 23-26. DOI:
对江西赣能股份丰城二期发电厂#6炉入炉煤进行煤质分析及热重分析后
选取具有代表性的煤种进行12种不同的分仓配煤方案
对锅炉热效率测试。分析配煤试验中锅炉飞灰可燃物、炉渣可燃物、排烟损失等因素对锅炉效率的影响
得出最佳的配煤掺烧方案
为锅炉燃烧优化调整提供科学依据。
Coal quality analysis and thermogravimetric analysis of No.6 boiler of Fengcheng Phase Ⅱ Power Plant were researched
and 12 different sub-warehouses blending programs for the representative coal were selected
and the boiler thermal efficiency tests were carried out.The impacts of the boiler fly ash combustible
the slag combustible
smoke damage in the trial to the boilers efficiency were analyzed
the optimum co-firing of coal blending were advanced
and the scientific basis for the boiler combustion optimization adjustment were provided.