Low-voltage ride through control strategy of permanent magnet direct-driven fan under DC capacitor voltage self-synchronization control
|更新时间:2025-12-20
|
Low-voltage ride through control strategy of permanent magnet direct-driven fan under DC capacitor voltage self-synchronization control
Issue 12, (2025)
作者机构:
1. 上海电力大学电气工程学院
2. 浙江大学电气工程学院
作者简介:
基金信息:
DOI:
CLC:
Published:2025
稿件说明:
移动端阅览
Wu Hao, Hu Pengfei, Xin Huanhai, et al. Low-voltage ride through control strategy of permanent magnet direct-driven fan under DC capacitor voltage self-synchronization control[J]. 2025, (12).
DOI:
Wu Hao, Hu Pengfei, Xin Huanhai, et al. Low-voltage ride through control strategy of permanent magnet direct-driven fan under DC capacitor voltage self-synchronization control[J]. 2025, (12).DOI:
Low-voltage ride through control strategy of permanent magnet direct-driven fan under DC capacitor voltage self-synchronization control
With the large-scale access of new energy such as wind power to the grid
the inertia of the power system is reduced
the frequency modulation ability is reduced
and the dynamic performance of the phase-locked loop under the weak current network is deteriorated. The effectiveness of the low-voltage ride-through control strategy of the permanent magnet direct-driven wind turbine based on the phase-locked loop grid-connected is greatly reduced. Therefore
a low-voltage ride-through control strategy of the permanent magnet direct-driven wind turbine based on the DC capacitor voltage self-synchronization control is proposed. Firstly
the control strategy introduces the DC capacitor voltage self-synchronization control unit into the unit control
so that the wind turbine does not need to rely on the traditional phase-locked loop structure for grid connection; Secondly
the super-capacitor energy storage system is paralleled at the DC side of the unit to build an integrated wind storage system to achieve power balance and improve the control of the grid-side converter
provide reliable reactive support during the low voltage ride through of the wind turbine
and improve the low voltage ride through capability of the permanent magnet direct-driven wind turbine; Finally
the effectiveness of the control strategy is verified by MATLAB/Simulink simulation.