Research on Earthing Fault Treatment Based on Primary and Secondary Integration Technology of Distribution Network
In order to solve the problems about the detection and quick isolation of single-phaseearthing faults in a small current grounding system
an earthing fault treatment scheme is proposed based on primary and secondary integration technology of distribution network. Through a complete set of primary and secondary fusion equipment and wavelet packet transient zero-sequence line selection technology
and combined with the use of incoming call closing
voltage free opening
closing on fault accelerated tripping
fault path priority and other strategies
the problems of single terminal line selection under multi-branch and multi-power supply modes are effectively solved. At the same time
combined with on site application cases