火电机组中由于煤炭资源短缺,燃料量往往会偏离设计值,品质恶化的燃料对机组锅炉影响较大,会导致受热面壁温超温、烟气温度偏差和减温水量偏大等问题。技术人员通过对运行过程中的主要参数进行分析判断,并对典型工况进行燃烧优化调整,以提高锅炉运行的安全性和经济性。以某电厂300 MW亚临界参数烟煤机组为例进行分析及相应燃烧调整,结果表明:通过对后屏过热器受热面壁温、转向室出口烟气温度偏差及再热器事故减温水量变化进行分析,同时结合制粉系统各磨煤机一次风速调平情况、SOFA风不同水平摆角的设置及周界风开度的变化情况,发现上述因素对锅炉运行有较大影响。由分析可知,各台磨煤机一次风速调平后,低负荷时通过调整下两层SOFA风水平摆角至合适位置,后屏过热器壁温明显下降,转向室A、B出口两侧烟温偏差控制在合理范围内;高负荷时将运行层喷口周界风开度调至试验开度,再热器减温水量下降至可控制的范围内。
In thermal power generating units
due to the shortage of coal resources
the fuel often deviates from the design value.The fuel with deteriorated quality has a significant impact on the boiler of the unit
which may lead to problems such as the over-temperature of the heating surface wall temperature
the deviation of the flue gas temperature
and the excessive amount of desuperheating water.Technicians analyze and judge the main parameters during the operation process
and carry out combustion optimization adjustments for typical working conditions to improve the safety and economic efficiency of the boiler operation.Taking a 300 MW subcritical parameters bituminous coal unit in a power plant as an example
it carries out the analysis and corresponding combustion adjustments.The results show that by analyzing the changes in the wall temperature of the heating surface of the rear platen superheater
the deviation of the flue gas temperature at the outlet of the turning chamber
and the amount of emergency desuperheating water of the reheater
and at the same time
combining with the situation of leveling the primary air velocity of each coal mill in the coal pulverizing system
the settings of different horizontal swing angles of the SOFA air
and the changes in the opening degree of the perimeter air.It is found that the above factors have a influence on the operation of the boiler.The specific manifestations are as follows: after leveling the primary air velocity of each coal mill
by adjusting the horizontal swing angles of the lower two layers of SOFA air to appropriate positions under low load conditions
the wall temperature of the rear platen superheater decreases significantly
and it controlls the flue gas temperature deviation on both sides of the outlets A and B of the turning chamber within a reasonable range.When the load is high
by adjusting the opening degree of the perimeter air of the nozzles on the operating layer to the test opening degree
the amount of desuperheating water of the reheater decreases to a controllable range.