Load-change control for thermal power units based on continuous regulation of back pressure
|更新时间:2025-09-28
|
Load-change control for thermal power units based on continuous regulation of back pressure
Thermal Power GenerationIssue 4, (2017)
作者机构:
1. 华北电力大学新能源电力系统国家重点实验室,北京,102206
2. 华北电力大学工业过程测控新技术与系统北京市重点实验室,北京,102206
3. 华北电力大学控制与计算机工程学院,北京,102206
作者简介:
基金信息:
DOI:
CLC:K323;TM621.4
Published Online:26 April 2017,
Published:2017
稿件说明:
移动端阅览
WANG Wei, LIU Huichao, YANG Wei, et al. Load-change control for thermal power units based on continuous regulation of back pressure[J]. Thermal power generation, 2017, (4).
DOI:
WANG Wei, LIU Huichao, YANG Wei, et al. Load-change control for thermal power units based on continuous regulation of back pressure[J]. Thermal power generation, 2017, (4).DOI:
Load-change control for thermal power units based on continuous regulation of back pressure
摘要
传统火电机组协调控制策略受限于锅炉侧的大迟延大惯性,其变负荷响应时间较长,一般不超过额定负荷的 2 %/min。本文提出一种基于背压调节的新型变负荷控制策略,在保证机组运行在安全背压的前提下,将循环水流量作为机组负荷的控制变量,当机组负荷出现偏差时,背压调节快速动作,减小偏差;而当机组负荷接近负荷指令时,背压调节恢复机组初始背压,保证机组运行的经济性,同时为下次变负荷调节做准备。在仿真机进行背压调节试验,结果表明湿冷机组循环水流量发生变化后 30 s 内机组背压和出力都将达到另一稳态值;在此基础上通过机理分析与试验曲线辨识,建立了湿冷机组循环水流量变化对机组出力影响的静态、动态模型;将背压连续调节作为机炉协调控制的辅助手段,建立了基于背压连续调节的新型变负荷控制策略,即背压调节用于机组变负荷控制的初始阶段,末期由协调控制完成。在某 300 MW 燃煤直流锅炉再热机组进行仿真,仿真结果表明该方案缩短了机组变负荷跨出死区的响应时间,提升了机组的变负荷速率。