Partial Discharge Defect Analysis of High - voltage Switchgear Based on Detection Technology Combined Ultrasonic and Electrical and Research on Its Improvement Measures
|更新时间:2026-02-13
|
Partial Discharge Defect Analysis of High - voltage Switchgear Based on Detection Technology Combined Ultrasonic and Electrical and Research on Its Improvement Measures
Vol. 42, Issue 1, Pages: 75-78(2019)
作者机构:
国网四川省电力公司电力科学研究院,
作者简介:
基金信息:
DOI:
CLC:TM564
Published:2019
稿件说明:
移动端阅览
Wang Jiayi. Partial Discharge Defect Analysis of High - voltage Switchgear Based on Detection Technology Combined Ultrasonic and Electrical and Research on Its Improvement Measures[J]. 2019, 42(1): 75-78.
DOI:
Wang Jiayi. Partial Discharge Defect Analysis of High - voltage Switchgear Based on Detection Technology Combined Ultrasonic and Electrical and Research on Its Improvement Measures[J]. 2019, 42(1): 75-78.DOI:
Partial Discharge Defect Analysis of High - voltage Switchgear Based on Detection Technology Combined Ultrasonic and Electrical and Research on Its Improvement Measures
The insulation defects can be found out and the operation state can be known accurately by using on - line detection technology. A typical case of partial discharge in 10 kV switchgear is described. By using transient earth voltage ( TEV) detection technology,acoustic emission ( AE) detection technology,and ultra - high frequency ( UHF) detection technology, the partial discharge signal in switchgear is detected. Through signal analysis and outage detection,the main reasons are found out and the improvement measures are put forward. The obtained results can provide a reliable guidance for the detection and improvement measures of partial discharge in switchgear.
Partial Discharge Defect Analysis of High - voltage Switchgear Based on Detection Technology Combined Ultrasonic and Electrical and Research on Its Improvement Measures
Application of Comprehensive Diagnosis Method for Internal Discharge Defects of GIS Supporting Insulator
Defect Detection and Analysis of Partial Discharge in 35 kV Switchgear Cabinet
Narrowband Interference Suppression of Partial Discharge Based on Short-time Fourier Transform
Development of An Ultrasound Partial Discharge Detection Device
Related Author
Yao Xiao
He Yuhang
Xue Zhihang
Yang Fan
Zhou Dianbo
Xiong Pan
Dai Hui
YANG Jie
Related Institution
State Grid Luzhou Electric Power Supply Company
State Grid Sichuan Electric Power Research Institute
Chengdu Aeronautic Polytechnic
Kunming Power Supply Bureau of Yunnan Power Grid Co., Ltd.
Urumqi Electric Power Supply Company,State Grid Xinjiang Electric Power