ANALYSIS AND SOLUTIONS AGAINST THE IMPACT OF ELECTROMAGNETIC VALVE STICKING ON OPERATION OF 220 MW STEAM TURBINE UNIT
|更新时间:2025-09-28
|
ANALYSIS AND SOLUTIONS AGAINST THE IMPACT OF ELECTROMAGNETIC VALVE STICKING ON OPERATION OF 220 MW STEAM TURBINE UNIT
Thermal Power GenerationVol. 38, Issue 5, Pages: 69-71(2009)
作者机构:
焦作电厂
作者简介:
基金信息:
DOI:
CLC:TK264.2
Published:2009
稿件说明:
移动端阅览
FU Jian-guo, CAO Jin-zhong, LIU Jin-chuan, et al. ANALYSIS AND SOLUTIONS AGAINST THE IMPACT OF ELECTROMAGNETIC VALVE STICKING ON OPERATION OF 220 MW STEAM TURBINE UNIT[J]. Thermal power generation, 2009, 38(5): 69-71.
DOI:
FU Jian-guo, CAO Jin-zhong, LIU Jin-chuan, et al. ANALYSIS AND SOLUTIONS AGAINST THE IMPACT OF ELECTROMAGNETIC VALVE STICKING ON OPERATION OF 220 MW STEAM TURBINE UNIT[J]. Thermal power generation, 2009, 38(5): 69-71.DOI:
ANALYSIS AND SOLUTIONS AGAINST THE IMPACT OF ELECTROMAGNETIC VALVE STICKING ON OPERATION OF 220 MW STEAM TURBINE UNIT
Presented in this paper are two operation failures caused by the sticking of electromagnetic valves in a steam turbine unit with a capacity of 220MW.Analysis was made to the impact of valve sticking on safe operation of the turbine unit.And some solutions were put forward to prevent such failures.