APPLICATION OF A MULTI-LAYER RADIAL BASIS NETWORK MODEL IN CALCULATION OF SPECIFIC ENTHALPY FOR EXHAUST STEAM FROM THE FINAL STAGE OF STEAM TURBINE
|更新时间:2025-09-28
|
APPLICATION OF A MULTI-LAYER RADIAL BASIS NETWORK MODEL IN CALCULATION OF SPECIFIC ENTHALPY FOR EXHAUST STEAM FROM THE FINAL STAGE OF STEAM TURBINE
Thermal Power GenerationVol. 38, Issue 7, Pages: 80-82(2009)
作者机构:
1. 华北水利水电学院动力系
2. 西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TK262
Published:2009
稿件说明:
移动端阅览
ZHANG Li-ping1, XU Qi1, WANG Wei-feng21.North China College of Water Conservancy and Hydro Power. APPLICATION OF A MULTI-LAYER RADIAL BASIS NETWORK MODEL IN CALCULATION OF SPECIFIC ENTHALPY FOR EXHAUST STEAM FROM THE FINAL STAGE OF STEAM TURBINE[J]. Thermal power generation, 2009, 38(7): 80-82.
DOI:
ZHANG Li-ping1, XU Qi1, WANG Wei-feng21.North China College of Water Conservancy and Hydro Power. APPLICATION OF A MULTI-LAYER RADIAL BASIS NETWORK MODEL IN CALCULATION OF SPECIFIC ENTHALPY FOR EXHAUST STEAM FROM THE FINAL STAGE OF STEAM TURBINE[J]. Thermal power generation, 2009, 38(7): 80-82.DOI:
APPLICATION OF A MULTI-LAYER RADIAL BASIS NETWORK MODEL IN CALCULATION OF SPECIFIC ENTHALPY FOR EXHAUST STEAM FROM THE FINAL STAGE OF STEAM TURBINE
摘要
现有的汽轮机末级排汽比焓计算模型存在一定的局限性
对此提出了一种改进的径向基(RBF)网络模型来计算汽轮机的排汽比焓值。计算结果表明
该模型收敛速度快
运算简便
预测精度较高
具有良好的实时性和有效性。采用此模型对某电厂的一台300MW机组汽轮机末级排汽比焓进行计算
其预测值分别为2 366.8 kJ/kg和2 377.2kJ/kg
而试验值分别为2 370.5 kJ/kg和2 375.1 kJ/kg
绝对误差分别为3.7 kJ/kg和2.1 kJ/kg
完全满足应用要求。
Abstract
Owing to certain limitation of existing model for calculating the specific enthalpy of exhaust steam from final stage of steam turbine
a modified radial basis network model has been established
which can be used for calculating the specific enthalpy value of exhaust steam from steam turbines.Result of calculation shows that the modified model has rapid converging speed
being easy and convenient in operation
having higher precision of prediction
boasting good behavior of real-time and effectiveness.The specific enthalpy of exhaust steam from final stage of steam turbine for a 300 MW unit in one power plant has been calculated by using the said model
the predicted values are 2 366.8 kJ/kg and 2 377.2 kJ/kg respectively
the tested value being 2 370.3 kJ/kg and 2 375.1 kJ/kg respectively
the absolute error being 3.7 kJ/kg and 2.1 kJ/kg respectively