DEEP SLIDING PARAMETER SHUTDOWN OF THE STEAM TURBINE IN COMBINED CYCLE UNIT
|更新时间:2025-09-28
|
DEEP SLIDING PARAMETER SHUTDOWN OF THE STEAM TURBINE IN COMBINED CYCLE UNIT
Thermal Power GenerationVol. 38, Issue 6, Pages: 71-74(2009)
作者机构:
华北电力科学研究院
作者简介:
基金信息:
DOI:
CLC:TK268
Published:2009
稿件说明:
移动端阅览
SI Pai-you, ZUO Chuan North China Electric Power Science Research Institute. DEEP SLIDING PARAMETER SHUTDOWN OF THE STEAM TURBINE IN COMBINED CYCLE UNIT[J]. Thermal power generation, 2009, 38(6): 71-74.
DOI:
SI Pai-you, ZUO Chuan North China Electric Power Science Research Institute. DEEP SLIDING PARAMETER SHUTDOWN OF THE STEAM TURBINE IN COMBINED CYCLE UNIT[J]. Thermal power generation, 2009, 38(6): 71-74.DOI:
DEEP SLIDING PARAMETER SHUTDOWN OF THE STEAM TURBINE IN COMBINED CYCLE UNIT
The realization of deep sliding parameter shutdown of steam turbine in unit with gas-steam combined cycle is still short of successful precedents.Through test of one deep sliding parameter shutdown for the steam turbine completed on a split-shaft combined cycle unit of GE9F class
the temperature in cylinder of steam turbine has been reduced to 253 ℃
having good effectiveness.An approach to the features and restraint factors for realizing deep sliding parameter shutdown on units with combined cycle has also been carried out.