ANALYSIS AND DISPOSAL OF VIBRATION ON ULTRA-SUPERCRITICAL TURBO-GENERATOR SET
|更新时间:2025-09-28
|
ANALYSIS AND DISPOSAL OF VIBRATION ON ULTRA-SUPERCRITICAL TURBO-GENERATOR SET
Thermal Power GenerationVol. 38, Issue 6, Pages: 61-64(2009)
作者机构:
1. 江苏省电力试验研究院有限公司
2. 南京航空航天大学金城学院
作者简介:
基金信息:
DOI:
CLC:TM621.3
Published:2009
稿件说明:
移动端阅览
CHEN Hua-gui1, TIAN Li21.Jiangsu Provincial Electric Power Testing and Research Institute Co Ltd. ANALYSIS AND DISPOSAL OF VIBRATION ON ULTRA-SUPERCRITICAL TURBO-GENERATOR SET[J]. Thermal power generation, 2009, 38(6): 61-64.
DOI:
CHEN Hua-gui1, TIAN Li21.Jiangsu Provincial Electric Power Testing and Research Institute Co Ltd. ANALYSIS AND DISPOSAL OF VIBRATION ON ULTRA-SUPERCRITICAL TURBO-GENERATOR SET[J]. Thermal power generation, 2009, 38(6): 61-64.DOI:
ANALYSIS AND DISPOSAL OF VIBRATION ON ULTRA-SUPERCRITICAL TURBO-GENERATOR SET
Directing against the abnormal vibration problem occurred during the time of start-up debugging of unit no.1 in Kanshan Power Plant
Jiangsu Province
through vibration monitoring
the collected vibration data and diagrams have been studied and analysed
finding out that the shaft vibration at bearings no.5 and no.6 of the generator was far in excess of the set standard mainly due to smaller gap on the outer oil retainer and impact-rubbing between movable and stationary parts in the generator.On basis of these
corresponding measures have been proposed
the tips of comb-teeth on the outer oil retainer being thinned out.After implementation
the problem of abnormal vibration of unit has been successfully solved