INFLUENCE OF COAL QUALITY VARIATION UPON COMBUSTION PERFORMANCE OF TANGENTIAL FIRING BOILERS
|更新时间:2025-09-28
|
INFLUENCE OF COAL QUALITY VARIATION UPON COMBUSTION PERFORMANCE OF TANGENTIAL FIRING BOILERS
Thermal Power GenerationVol. 38, Issue 8, Pages: 59-64(2009)
作者机构:
华北电力大学能源与动力工程学院
作者简介:
基金信息:
DOI:
CLC:TK227.1
Published:2009
稿件说明:
移动端阅览
LI Jun, YAN Wei-ping, LIU Ya-zhiCollege of Energy and Power Engineering. INFLUENCE OF COAL QUALITY VARIATION UPON COMBUSTION PERFORMANCE OF TANGENTIAL FIRING BOILERS[J]. Thermal power generation, 2009, 38(8): 59-64.
DOI:
LI Jun, YAN Wei-ping, LIU Ya-zhiCollege of Energy and Power Engineering. INFLUENCE OF COAL QUALITY VARIATION UPON COMBUSTION PERFORMANCE OF TANGENTIAL FIRING BOILERS[J]. Thermal power generation, 2009, 38(8): 59-64.DOI:
INFLUENCE OF COAL QUALITY VARIATION UPON COMBUSTION PERFORMANCE OF TANGENTIAL FIRING BOILERS
Based on coal quality variation and combustion performance change after retrofit of boiler equipment in one power plant
through numerical calculation and theoritical analysis
the problems existing on the boiler
such as high temperature of exhaust flue gas
large quantity of desuperheating water needed for the superheater and reheater
have been analysed
and the influence of coal quality variation upon combustion performance in the boiler being summarized up.Though the ignition temperature of bituminous pulverized coal and air flow(800 ℃) is about 100 ℃ lower than that of lean coal(900 ℃)
but because of operation parameters' change in the coal-pulverizing system and the burners' system
the initial temperature of bituminou coal and primary air flow(75 ℃) is more lower than that of lean coal(160 ℃)
and the flow rate of promary air increases by a big margin(from 113 t/h to 231 t/h)
the heat quantity needed for igition of bituminous coal is about 30% greater than that for lean coal
thereby
making the combustion in the furnace to be postponed
and the flame centre to shift upward
the quantity of desuperheating water needed for superheated steam to be increased.At the same time
the result of thermodynamic calculation in furnace after reducing elevation of burners by 200 mm and 500 mm
and the result of thermodynamic calculation for the entire unit after increasing the row of tubes for economizer have been given.