OPTIMIZATION OF PIPE-BLOWING TECHNOLOGY UNDER STABLE PRESSURE FOR SUPERCRITICAL ONCE-THROUGH BOILER
|更新时间:2025-09-28
|
OPTIMIZATION OF PIPE-BLOWING TECHNOLOGY UNDER STABLE PRESSURE FOR SUPERCRITICAL ONCE-THROUGH BOILER
Thermal Power GenerationVol. 38, Issue 12, Pages: 41-43(2009)
作者机构:
1. 山东电力研究院
2. 大唐黄岛发电厂
作者简介:
基金信息:
DOI:
CLC:TK229.2
Published:2009
稿件说明:
移动端阅览
HAO Wei-dong1, WEI Kun2, QI Yong-mei2, et al. OPTIMIZATION OF PIPE-BLOWING TECHNOLOGY UNDER STABLE PRESSURE FOR SUPERCRITICAL ONCE-THROUGH BOILER[J]. Thermal power generation, 2009, 38(12): 41-43.
DOI:
HAO Wei-dong1, WEI Kun2, QI Yong-mei2, et al. OPTIMIZATION OF PIPE-BLOWING TECHNOLOGY UNDER STABLE PRESSURE FOR SUPERCRITICAL ONCE-THROUGH BOILER[J]. Thermal power generation, 2009, 38(12): 41-43.DOI:
OPTIMIZATION OF PIPE-BLOWING TECHNOLOGY UNDER STABLE PRESSURE FOR SUPERCRITICAL ONCE-THROUGH BOILER
摘要
大唐黄岛发电厂5号机组超临界直流锅炉采用简单疏水大气扩容式起动系统
在采用等离子点火起动过程中不能实现稳压无油耗吹管。通过机组起动过程中的热平衡分析
对稳压吹管技术进行了优化
实现了超临界直流锅炉的零油耗稳压吹管
经济效益明显。
Abstract
The start-up system of simple drain and atmospheric flashing has been used for supercritical once-through boielr of unit NO.5 in Datang Huangdao Power Plant
in the process of start-up using plasma ignition
the pipe-blowing under stable pressure without oil consumption can't be realized.Through heat balance analysis in the start-up process of unit
the optimization in pipe-blowing technology under stable pressure has been carried out
the pipe-blowing technology under stable pressure with zero oil consumption for supercritical once-through boiler being realized
STUDY ON DYNAMIC BEHAVIOR OF ONCE-THROUGH BOILER EUIPPED FOR SUPERCRITICAL 600 MW UNIT
Experimental study on banked fire for peak regulation of supercritical circulating fluidized bed units
Simulation modelling of power system for supercritical units considering dynamic heat exchange of once-through boiler
Experimental study on start-stop peak regulation of a 350 MW supercritical circulating fluidized bed coal-fired power unit
PRELIMINARY ANALYSIS OF REQUIREMENTS TO WATER-WALL SYSTEM PERFORMANCE FOR SERVICE OPERATION OF SUPERCRITICAL PRESSURE ONCETHROUGH BOILER OF 600MW UNITS
Related Author
WANG Zhigang
LEI Zhaotuan
ZHANG GuangcaiXi'an Thermal Power Research Institute Co Ltd
TONG Boheng
LI Yu
MA Lele
XU Yongwei
ZHAO Binbin
Related Institution
Xi'an Thermal Power Research Institute Co., Ltd
North China Electric Power Research Institute Co., Ltd
Jijian Investment Shouyang Thermal Power Co., Ltd
Department of Energy and Power Engineering, Tsinghua University
Department of Electrical Engineering and Applied Electronic Technology, Tsinghua University