CAUSE ANALYSIS OF HIGH TEMPERATURE CORROSION ON WATER WALL OF SUPERCRITICAL ONCE-THROUGH BOILERS AND COUNTERMEASURES THEREOF
更新时间:2025-09-28
    • CAUSE ANALYSIS OF HIGH TEMPERATURE CORROSION ON WATER WALL OF SUPERCRITICAL ONCE-THROUGH BOILERS AND COUNTERMEASURES THEREOF

    • Thermal Power Generation   Vol. 38, Issue 12, Pages: 106-108(2009)
    • CLC: TK224.94
    • Published:2009

    移动端阅览

  • ZHONG Wan-li, WU Shi-deng, ZENG Fan-yun Guangdong Electric Power Science Research Institute. CAUSE ANALYSIS OF HIGH TEMPERATURE CORROSION ON WATER WALL OF SUPERCRITICAL ONCE-THROUGH BOILERS AND COUNTERMEASURES THEREOF[J]. Thermal power generation, 2009, 38(12): 106-108. DOI:

  •  
  •  

0

Views

343

下载量

28

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

High temperature corrosion in wall-firing boiler:reason analysis and treatment
PRACTICE OF OXYGEN-ADDING TREATMENT FOR FEED-WATER OF ONCE-THROUGH BOILERS EQUIPPED FOR SUPERCRITICAL UNITS IN GUOHUA TAICANG POWER PLANT
High combustible content in slag from a supercritical 600MW unit once-through boiler:underlying cause analysis and optimization adjustment
Simulink based dynamic characteristics simulation for water wall on an ultra supercritical boiler
Operation adjustment for high temperature corrosion in water wall of supercritical opposed firing boiler

Related Author

LIU Honggang
ZHANG Guangcai
WANG Zhigang
LIAO Xiaochun
CHEN Minsheng
CHEN Yiyang
GU Qing-hua
FU Yu Guohua Taicang Power Generation Co Ltd

Related Institution

Xi'an Thermal Power Research Institute Co., Ltd
Guangdong Yuedian Jinghai Power Generation Co., Ltd
Guohua Taicang Power Generation Co., Ltd
Xi'an Thermal Power Research Institute Co., Ltd. Suzhou Branch
School of Energy and Power Engineering, Xi'an Jiaotong University
0