The cracks are easily occurred on tube sections at weld joints of sealing plates in boilers due to the working stress of tube proper
the thermal stress resulted from different superimposed thermal expansion coefficients
and additional tension stress caused by sway of tube rows
and the said cracks can't be effectively detected by using other detection methods
such as liquid penetrition inspection
magnetic powder detection
and magnetic memory method etc.
and only the ultrasonic detection can be used for this purpose.The selection of ultrasonic probe
the operation method
and the evaluation of defects in ultrasonic detection have been presented.The ultrasonic detection can provide detection basis for diagnosis of early cracks occurred at weld joints of the sealing plates.