ANALYSIS OF TECHNICAL AND ECONOMIC EFFICIENCY OF ABOLISHING BY-PASS FLUE DUCT IN WET DESULPHURIZATION SYSTEM
|更新时间:2025-09-28
|
ANALYSIS OF TECHNICAL AND ECONOMIC EFFICIENCY OF ABOLISHING BY-PASS FLUE DUCT IN WET DESULPHURIZATION SYSTEM
Thermal Power GenerationVol. 38, Issue 10, Pages: 1-4(2009)
作者机构:
中电投远达环保工程有限公司
作者简介:
基金信息:
DOI:
CLC:X701.3
Published:2009
稿件说明:
移动端阅览
ZHANG Jin-lun, SUI Jian-cai, LIAO Neng-bin, et al. ANALYSIS OF TECHNICAL AND ECONOMIC EFFICIENCY OF ABOLISHING BY-PASS FLUE DUCT IN WET DESULPHURIZATION SYSTEM[J]. Thermal power generation, 2009, 38(10): 1-4.
DOI:
ZHANG Jin-lun, SUI Jian-cai, LIAO Neng-bin, et al. ANALYSIS OF TECHNICAL AND ECONOMIC EFFICIENCY OF ABOLISHING BY-PASS FLUE DUCT IN WET DESULPHURIZATION SYSTEM[J]. Thermal power generation, 2009, 38(10): 1-4.DOI:
ANALYSIS OF TECHNICAL AND ECONOMIC EFFICIENCY OF ABOLISHING BY-PASS FLUE DUCT IN WET DESULPHURIZATION SYSTEM
The status quo of abolishing by-pass flue duct in wet flue gas desulphurization(FGD) system at home and abroad has been described
the factors affecting the abolishing by-pass flue duct in wet FGD system being analysed
and a technical scheme of abolishing by-pass flue duct in wet FGD system being put forward.The economic efficiency analysis of desulphurization for 2×300 MW units
2×600 MW units
and 2×1 000 MW units shows that the abolishment of by-pass flue duct in single tower technology and in double tower technology for GFD will increase capital investment by 3%~10% and 10%~15% respectively.The capital investment for double tower technology is about 5% more than that in single tower scheme.After abolishing the by-pass flue duct in three power plants
the electricity consumption in operation can be reduced by 1.5 million kW·h
2.5 million kW·h
and 3.25 million kW·h respectively
the cost of operation in FGD system can be saved by 0.45
0.75
and 0.98 million yuan respectively
and the maintenance expense can be decreased by a big margin.