THE MOVING LOCUS OF UREA SOLUTION ATOMIZING PARTICLES IN FURNACE OF BOILER
|更新时间:2025-09-28
|
THE MOVING LOCUS OF UREA SOLUTION ATOMIZING PARTICLES IN FURNACE OF BOILER
Thermal Power GenerationVol. 39, Issue 2, Pages: 18-23(2010)
作者机构:
1. 浙江大学能源清洁利用国家重点实验室
2. 浙江大学能源清洁利用国家重点实验室
作者简介:
基金信息:
DOI:
CLC:X701.3
Published:2010
稿件说明:
移动端阅览
CHEN Zhen-chao, YANG Wei-juan, ZHOU Jun-hu, et al. THE MOVING LOCUS OF UREA SOLUTION ATOMIZING PARTICLES IN FURNACE OF BOILER[J]. Thermal power generation, 2010, 39(2): 18-23.
DOI:
CHEN Zhen-chao, YANG Wei-juan, ZHOU Jun-hu, et al. THE MOVING LOCUS OF UREA SOLUTION ATOMIZING PARTICLES IN FURNACE OF BOILER[J]. Thermal power generation, 2010, 39(2): 18-23.DOI:
THE MOVING LOCUS OF UREA SOLUTION ATOMIZING PARTICLES IN FURNACE OF BOILER
The atomizing particle size of a Y-jet partial-inner-mixed pneumatic atomizing selective non-catalytic reduction(SNCR) lance is decreasing along with the increase of gas loss rate
and with the increase of atomizing medium in case of the gas loss rate being the same.The moving locus of atomizing pariticles injected into a 100 MW four-corner tangential firing pulverized coal boiler has been studied by using CFD software platform and adopting numerical simulation method.It is obtained that the best injected atomizing particle size is between 0.3~0.5 mm in the case of injection rate being equal to 25 m/s.A denitrification test with injection of urea solution into boiler has been carried out
the denitrification efficiency is inceasing at first
and then decreasing along with the increase of atomizing particle size.In the event of the chemical equivalence of ammoniacal nitrogen being equal to 1.5
the maximum denitrification efficiency can reach 58%.