ANALYSIS OF FATIGUE LIFE FOR CONTACTING-TYPE FLEXIBLE SEAL ON ROTARY AIR PREHEATER BASED ON ANSYS
|更新时间:2025-09-28
|
ANALYSIS OF FATIGUE LIFE FOR CONTACTING-TYPE FLEXIBLE SEAL ON ROTARY AIR PREHEATER BASED ON ANSYS
Thermal Power GenerationVol. 39, Issue 1, Pages: 32-35(2010)
作者机构:
北京化工大学诊断与自愈工程研究中心
作者简介:
基金信息:
DOI:
CLC:TK223.34
Published:2010
稿件说明:
移动端阅览
WANG Qing-feng, HE Li-dongResearch Centre of Diagnosis and Self-recovery Engineering. ANALYSIS OF FATIGUE LIFE FOR CONTACTING-TYPE FLEXIBLE SEAL ON ROTARY AIR PREHEATER BASED ON ANSYS[J]. Thermal power generation, 2010, 39(1): 32-35.
DOI:
WANG Qing-feng, HE Li-dongResearch Centre of Diagnosis and Self-recovery Engineering. ANALYSIS OF FATIGUE LIFE FOR CONTACTING-TYPE FLEXIBLE SEAL ON ROTARY AIR PREHEATER BASED ON ANSYS[J]. Thermal power generation, 2010, 39(1): 32-35.DOI:
ANALYSIS OF FATIGUE LIFE FOR CONTACTING-TYPE FLEXIBLE SEAL ON ROTARY AIR PREHEATER BASED ON ANSYS
摘要
基于有限元通用软件ANSYS的疲劳寿命分析方法
运用ANSYS的FATIGUE模块
将有限元方法和疲劳寿命分析理论相结合
对回转式空气预热器接触式柔性密封进行三维参数化建模
并编制APDL命令流
建立疲劳分析文件对回转式空气预热器接触式柔性密封进行了疲劳寿命分析。结果表明
回转式空气预热器接触式柔性密封的疲劳寿命为8年。
Abstract
Adopting the fatigue life analysis method based on ANSYS
which combines the finite element method with the fatigue life analyzing theory by using FATIGUE module of ANSYS
a three-dimensional parameter model for contacting-type flexible seal on the rotary air preheater has been established
the APDL command stream being compiled
and the documents for fatigue life analysis being built
and then the fatigue life of contacting-type flexible seal for the rotary air preheater has been analysed.Results show that the fatigue life of contacting-type flexible seal for the rotary preheater is eight years.
ANALYSIS OF PLATE-TURNOVER PHENOMENON CONCERNING RUDUCTION GEARBOX OF 29-VI(T) 1780 TYPE AIR PREHEATER SURPASSING THE CLUTCH COUPLING AND TECHNICAL RETROFITTING OF THE STARTING-UP CIRCUIT
INFLUENCE OF SCR DENITRIFICATION FACILITY UPON THE BOILER STRUCTURE
ANALYSIS OF EFFECTIVENESS AND ECONOMIC EFFICIENCY FOR ON-LINE WATER FLUSHING OF AIR PREHEATER
CAUSE ANALYSIS OF HIGH EXHAUST GAS TEMPERATURE FROM HG-450/13.7-YM24 BOILER AND RETROFIT THEREOF
RETROFIT OF ROTARY AIR PREHEATER FOR ELIMINATING AIR-LEAKAGE