CHANG Liang, WU Wenlong Henan Electric Power Testing and Research Institute. CAUSE ANALYSIS OF SEVERE FOULING ON ULTRAFILTRATION MEMBRANE AND OFF-LINE CHEMICAL CLEANING THEREOF[J]. Thermal power generation, 2010, 39(5): 101-104.
DOI:
CHANG Liang, WU Wenlong Henan Electric Power Testing and Research Institute. CAUSE ANALYSIS OF SEVERE FOULING ON ULTRAFILTRATION MEMBRANE AND OFF-LINE CHEMICAL CLEANING THEREOF[J]. Thermal power generation, 2010, 39(5): 101-104.DOI:
CAUSE ANALYSIS OF SEVERE FOULING ON ULTRAFILTRATION MEMBRANE AND OFF-LINE CHEMICAL CLEANING THEREOF
Cause analysis of fouling on ultrafiltration membrane in make up water treatment system of one power plant has been carried out.By using the conventional method and ICP spectroscopy technology
the composition of fouling has been analysed
the result shows the fouling is constituted from organic matters
silicon
and iron etc..Owing to the interaction between organic and inorganic matters
the difficulty of chemical cleaning is increased.A chemical cleaning test for a single membrane element has been carried out by using the method of off-line chemical cleaning
having good effectiveness.After chemical cleaning
the flow rate of water produced by a single membrane element has increased from 2~3 m3/h to 8~9 m3/h
the pressure on dense-water side being enhanced to about 0.08 MPa
the flow rate of effluent water from equipment of a complete set reaches 45~55 m3/h
the pressure difference of water between inlet and outlet is about 0.02 MPa