TEST FOR OPERATION OPTIMIZATION OF CFB BOILERS MIXEDLY BURNING HIGH-SULPHUR PETROLEUM COKE WITH COAL
|更新时间:2025-09-28
|
TEST FOR OPERATION OPTIMIZATION OF CFB BOILERS MIXEDLY BURNING HIGH-SULPHUR PETROLEUM COKE WITH COAL
Thermal Power GenerationVol. 39, Issue 5, Pages: 72-76(2010)
作者机构:
浙江大学热能工程研究所
作者简介:
基金信息:
DOI:
CLC:TK227
Published:2010
稿件说明:
移动端阅览
XU Yaobing, WANG Qinhui, YU Chunjiang, et al. TEST FOR OPERATION OPTIMIZATION OF CFB BOILERS MIXEDLY BURNING HIGH-SULPHUR PETROLEUM COKE WITH COAL[J]. Thermal power generation, 2010, 39(5): 72-76.
DOI:
XU Yaobing, WANG Qinhui, YU Chunjiang, et al. TEST FOR OPERATION OPTIMIZATION OF CFB BOILERS MIXEDLY BURNING HIGH-SULPHUR PETROLEUM COKE WITH COAL[J]. Thermal power generation, 2010, 39(5): 72-76.DOI:
TEST FOR OPERATION OPTIMIZATION OF CFB BOILERS MIXEDLY BURNING HIGH-SULPHUR PETROLEUM COKE WITH COAL
In order to solve the problems occurred in operation of a CFB boiler mixedly burning high-sulphur petroleum coke with coal
such as high carbon content in fly ash
low boiler efficiency
and low desulphurization efficiency etc.
an operation test has been carried out on two 310 t/h CFB boilers
the excess air coefficient
the bed temperature
the Ca/S ratio
and the ratio of petroleum coke to coal being adjusted.Tset shows that the optimal operation parameters are as follows:the excess air coefficient is 1.15~1.2
the bed temperature is 890~900 ℃
and the ratio of petroleum coke to coal is 2.5∶1~3∶1.On this basis
an optimization test of boiler performance has been conducted.After optimization
the carbon content in fly ash has decreased 8.05% than that under reference operating condition
the boiler efficiency has increased 2.49%
and the concentration of SO2 emission has reduced from 834.42 μL/L to 480 μL/L.