STUDY ON AND COUNTERMEASURES FOR ERRORS APPEARED IN MEASUREMENT OF DIFFERENTIAL EXPANSION IN LOW-PRESSRUE CYLINDER FOR 600 MW STEAM TURBINE MANUFACTURED BY ALSTOM
|更新时间:2025-09-28
|
STUDY ON AND COUNTERMEASURES FOR ERRORS APPEARED IN MEASUREMENT OF DIFFERENTIAL EXPANSION IN LOW-PRESSRUE CYLINDER FOR 600 MW STEAM TURBINE MANUFACTURED BY ALSTOM
Thermal Power GenerationVol. 38, Issue 12, Pages: 78-81(2009)
作者机构:
国电浙江北仑发电厂
作者简介:
基金信息:
DOI:
CLC:TK31
Published:2009
稿件说明:
移动端阅览
RONG Zhao-yang, HAN Ji-wen Guodian Beilun Power Plant. STUDY ON AND COUNTERMEASURES FOR ERRORS APPEARED IN MEASUREMENT OF DIFFERENTIAL EXPANSION IN LOW-PRESSRUE CYLINDER FOR 600 MW STEAM TURBINE MANUFACTURED BY ALSTOM[J]. Thermal power generation, 2009, 38(12): 78-81.
DOI:
RONG Zhao-yang, HAN Ji-wen Guodian Beilun Power Plant. STUDY ON AND COUNTERMEASURES FOR ERRORS APPEARED IN MEASUREMENT OF DIFFERENTIAL EXPANSION IN LOW-PRESSRUE CYLINDER FOR 600 MW STEAM TURBINE MANUFACTURED BY ALSTOM[J]. Thermal power generation, 2009, 38(12): 78-81.DOI:
STUDY ON AND COUNTERMEASURES FOR ERRORS APPEARED IN MEASUREMENT OF DIFFERENTIAL EXPANSION IN LOW-PRESSRUE CYLINDER FOR 600 MW STEAM TURBINE MANUFACTURED BY ALSTOM
Directing against the problem of differential expansion in low-pressrue cylinder of 600 MW steam burbine manufactured by ALSTOM is far larger in the winter season
and affecting safe and economic operation of the unit
the probe of differential expansion in low-pressure cylinder
the cooling of prebox
and the temperature characters of prebox have been tested.It is believed that the main causes leading to large error in measurement of differential expansion of low-pressure cylinder in winter season are the bad quality of prebox WL172A+AO--02-11C used for measuring differential expansion in low-pressure cylinder
and the remarkable influence of ambient temperature variation upon the output value of measurement.For this
the position of prebox has been removed
making the influence of ambient temperature in winter season to be substantially reduced
ANALYSIS OF ABNORMAL AXIAL DISPLACEMENT IN STEAM TURBINE OF 600 MW UNIT MADE BY ALSTOM CORPORATION AND HANDLING THEREOF
DESIGN OPTIMIZATION OF DIRECT AIR COOLING UNIT AND ANALYSIS ABOUT INFLUENCE OF AMBIENT TEMPERATURE VARIATION UPON ECONOMIC EFFICIENCY IN UNIT'S OPERATION
CALCULATION AND ANALYSIS OF CHARACTERISTICS UNDER OFF-DESIGN CONDITION OF DIRECT AIR COOLING SYSTEM FOR AIR COOLING UNITS
ANALYSIS OF LVDT FAILURE FOR GOVENOR VALVE OF STEAM TURBINE EQUIPPED FOR SUBCRITICAL 600 MW UNIT AND RETROFIT THEREOF
Reason analysis for the fifth stage blade fracture in low pressure cylinder of a 600MW unit steam turbine
Related Author
XIE Cheng
ZHOU Yi-zheGuodian Beilun Power Generation Co Ltd no.1
LIANG Bo
TANG Sheng-liChongqing University
LI Gao-chao
ZHU Bao-tian
CHEN Sheng-li
PENG Na Xi'an Thermal Power Research Institute Co Ltd