Several key problems of preventing over-temperature tube-burst in operation of high-temperature tube-panel on superheater and reheater of supercritical and ultra-supercritical boilers have been expounded
including oxide skin produced in the tubes
suddenly occurred disturbance
combustion adjustment
heat-Absorbing deviation along the direction of panel width
thermal deviation on the same panel
flue gas temperature deviation at two sides of the furnace outlet
water-spraying amount for final-stage superheater
and thermal insulation of temperature-measuring points at outlet side of the furnace etc..It is recommended to adopt on-line monitoring device for wall temperature in the furnace