TEST STUDY ON INFLUENCE OF THE REVERSED TANGENTIAL ANGLE FOR SEPARATING OVER-FIRED AIR UPON THE AERODYNAMIC FIELD IN FURNACE
更新时间:2025-09-28
    • TEST STUDY ON INFLUENCE OF THE REVERSED TANGENTIAL ANGLE FOR SEPARATING OVER-FIRED AIR UPON THE AERODYNAMIC FIELD IN FURNACE

    • Thermal Power Generation   Vol. 39, Issue 5, Pages: 13-17(2010)
    • CLC: TK221
    • Published:2010

    移动端阅览

  • QI Hongmei, HUI Shien, CUI Dawei College of Energy and Power Engineering. TEST STUDY ON INFLUENCE OF THE REVERSED TANGENTIAL ANGLE FOR SEPARATING OVER-FIRED AIR UPON THE AERODYNAMIC FIELD IN FURNACE[J]. Thermal power generation, 2010, 39(5): 13-17. DOI:

  •  
  •  

0

Views

198

下载量

15

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

THE EFFECTS OF SEPARATING OVER-FIRED AIR SYSTEM FOR BOILERS EQUIPED IN GUOHUA TAI CANG POWER PLANT
SLAGGING PREVENTION TECHNOLOGY FOR BURNING SHENHUA COAL IN TANGENTIAL FIRING BOILERS
STUDY ON NUMERICAL SIMULATION OF DECREASING NOx EMISSION FROM COAL-FIRED BOILERS BASED ON BFA AND OFA
The influence of primary air rate variation on performance of a tangentially fired lignite boiler
CAUSES LEADING TO SLAGGING IN FURNACE OF TANGENTIAL FIRING PULVERIZED COAL BOILER AND PREVENTIVE MEASURES THEREOF

Related Author

ZHANG Chun-lin1
XUE Ning21. Guohua Taicang Power Plant
WANG Pingang1
SONG Chang2
WANG Yueming31.Shenhua Group Corporation
CHEN Sunhang
Zhou Zhijun
ZHANG Xiuxia

Related Institution

Guohua Taicang Power Plant
Xi'an Thermal Power Research Institute Co., Ltd
Shenhua Group Co., Ltd
Shenhua Guohua Electric Power Branch
State Key Laboratory of Clean Energy Utilization, Zhejiang University
0