您当前的位置:
首页 >
文章列表页 >
CAUSE ANALYSIS OF FRACTURE OCCURRED ON THERMOWELL TO OUTLET HEADER OF THE PLATEN SUPERHEATER
更新时间:2025-09-28
    • CAUSE ANALYSIS OF FRACTURE OCCURRED ON THERMOWELL TO OUTLET HEADER OF THE PLATEN SUPERHEATER

    • Thermal Power Generation   Vol. 39, Issue 4, Pages: 100-101(2010)
    • CLC: TK223.32
    • Published:2010

    移动端阅览

  • JIN Feng, SONG Li, ZHANG Wuneng, et al. CAUSE ANALYSIS OF FRACTURE OCCURRED ON THERMOWELL TO OUTLET HEADER OF THE PLATEN SUPERHEATER[J]. Thermal power generation, 2010, 39(4): 100-101. DOI:

  •  
  •  