The causes of fracture on thermowell to outlet header for boiler no.2 in one power generation company have been analysed
results show that the causes leading to fracture are as follows:unreasonable structure of the thermowell has intensified the temperature rise and vibration under cyclic stress at location of fracture appeared on the thermowell
the existence of σ-phase due to rapid ageing of material texture and welding leads to fracture of the thermowell.For this
it is recommended to fabricate intermal thread on inner wall of the thermowell
making its structure to be more stable and reliable