STUDY ON DESIGN OF STATE FEED-BACK CONTROL SYSTEM FOR STEAM TEMPERATURE PROCESS IN BOILERS
|更新时间:2025-09-28
|
STUDY ON DESIGN OF STATE FEED-BACK CONTROL SYSTEM FOR STEAM TEMPERATURE PROCESS IN BOILERS
Thermal Power GenerationVol. 39, Issue 4, Pages: 31-35(2010)
作者机构:
上海电力学院电力与自动化工程学院
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2010
稿件说明:
移动端阅览
YANG Ping, YU Jie, SUN Yuzhen, et al. STUDY ON DESIGN OF STATE FEED-BACK CONTROL SYSTEM FOR STEAM TEMPERATURE PROCESS IN BOILERS[J]. Thermal power generation, 2010, 39(4): 31-35.
DOI:
YANG Ping, YU Jie, SUN Yuzhen, et al. STUDY ON DESIGN OF STATE FEED-BACK CONTROL SYSTEM FOR STEAM TEMPERATURE PROCESS IN BOILERS[J]. Thermal power generation, 2010, 39(4): 31-35.DOI:
STUDY ON DESIGN OF STATE FEED-BACK CONTROL SYSTEM FOR STEAM TEMPERATURE PROCESS IN BOILERS
摘要
针对电站锅炉蒸汽温度应用单纯状态反馈控制存在的问题
提出了2种确定期望极点的方法。若采用添加设定值跟踪增益的方案解决单纯状态反馈极点配置
则不能保证稳态性能
对此给出了状态反馈极点配置设计原则。仿真试验结果表明
满足控制量约束条件取决于状态反馈极点配置的右边界。
Abstract
Directing against the problems existing in feed-back control of steam temperature from utility boilers by using merely single state
two methods for determining the desired limits have been put forward.In case of adopting the scheme of adding set-value tracking gain to solve the configuration of limits in simple state feed-back
the stable performance can't be ensured.For this
a design principle for configuration of limits has been given.Result of emulation test shows that the satisfaction of constrained conditions for controlled quantity is determined by the right boundary of limit configuration in state feed-back.
CONTROL MEASURES FROM BOILER SIDE IN LOAD REJECTION TEST OF SUPERCRITICAL 600 MW UNIT
ANALYSIS AND OPTIMIZATION OF RUN BACK CONTROL STRATEGY FOR ULTRA-SUPERCRITICAL 1000 MW UNIT
STEAM TEMPERATURE CONTROL STRATEGY FOR PIPE-BLOWING BY USING STEAM UNDER CONDITION WITHOUT BOILER WATER CIRCULATING PUMP FOR ULTRA-SUPERCRITICAL 1 000 MW UNIT
Research on main and reheat steam temperature lifting method for ultra supercritical 1 000 MW unit double-tangential circular boiler
Development and numerical simulation for a high efficiency steam soot blower
Related Author
DUAN Bao
LI Feng
ZHANG Zhijun North China Electric Power Research Institute (Xi'an) Co Ltd
CHEN Xiaoqiang
LUO Zhihao
YIN Feng Zhejiang Provincal Electric Power Testing and Research Institute
LI Xinhu Guangzhou Yueneng Electric Power Science and Technology Development Co Ltd
LU Quan
Related Institution
North China Electric Power Research Institute (Xi'an) Co., Ltd
Zhejiang Electric Power Test and Research Institute
Guangzhou Yueneng Electric Power Technology Development Co., Ltd
School of Environmental Science Engineering, North China Electric Power University
Guohua Sanhe Power Generation Limited Liability Company