ANALYSIS AND CALCULATION OF HEAT TRANSFER MODEL FOR ROLLING-DRUM SLAG COOLER OF CFB BOILERS EQUIPED FOR 300 MW UNIT
|更新时间:2025-09-28
|
ANALYSIS AND CALCULATION OF HEAT TRANSFER MODEL FOR ROLLING-DRUM SLAG COOLER OF CFB BOILERS EQUIPED FOR 300 MW UNIT
Thermal Power GenerationVol. 39, Issue 1, Pages: 18-20(2010)
作者机构:
秦皇岛秦热发电有限责任公司
作者简介:
基金信息:
DOI:
CLC:TK229.6
Published:2010
稿件说明:
移动端阅览
LIU KunQinhuangdao Qinre Power Generation Co Ltd. ANALYSIS AND CALCULATION OF HEAT TRANSFER MODEL FOR ROLLING-DRUM SLAG COOLER OF CFB BOILERS EQUIPED FOR 300 MW UNIT[J]. Thermal power generation, 2010, 39(1): 18-20.
DOI:
LIU KunQinhuangdao Qinre Power Generation Co Ltd. ANALYSIS AND CALCULATION OF HEAT TRANSFER MODEL FOR ROLLING-DRUM SLAG COOLER OF CFB BOILERS EQUIPED FOR 300 MW UNIT[J]. Thermal power generation, 2010, 39(1): 18-20.DOI:
ANALYSIS AND CALCULATION OF HEAT TRANSFER MODEL FOR ROLLING-DRUM SLAG COOLER OF CFB BOILERS EQUIPED FOR 300 MW UNIT
摘要
在对CFB锅炉滚筒冷渣器传热模型分析的基础上
利用正交试验方法对秦皇岛秦热发电有限责任公司6号炉3号滚筒冷渣器进行了影响其传热的分析试验
并进行了热量平衡计算。结果表明
滚筒冷渣器传热模型分析较为合理
在影响滚筒冷渣器传热的3个因素中
排渣粒径的影响最大
填充量的影响其次
转速的影响最小。为此
建议在排渣量少时
尽量少启动冷渣器
并使其填充量达到40%左右为宜。同时
还可采取降低入炉煤粒度以及保证合理的转速等方法
以提高滚筒冷渣器的传热系数。
Abstract
On the basis of analysing the heat transfer model of rolling-drum slag cooler for circulating fluidized bed(CFB) boiler
an analysis test of factors affecting heat transfer of rolling-drum slag cooler no.3 of boiler no.6 in Qinhuangdao Qinre Power Generation Co Ltd has been carried out by using the orthoganal test method
and the heat equilibrum being calculated.Results show that the analysis of heat transfer model for the rolling-drum slag cooler is more reasonable.In three factors affecting the heat transfer for said slag cooler
the influence of particle size concerning discharged slag is the maximum
the influence of filling amount is the next
and the influence of rotation speed is the minimum.For this
it is recommended that the said slag cooler has to be put into service as fewer as possible during the time of small quantity of slag
and making the filling amount of the slag cooler to be suitable about 40%.At the same time
the particle size of pulverized coal incoming into the furnace can also be reduced
and the reasonable rotation speed of rolling-drum slag cooler should be ensured
so as to enhance the heat transfer coefficiency of the slag cooler.