CAUSE ANALYSIS OF FIRE-RESISTANT OIL'S RESISTIVITY SURPASSING SET STANDARD IN OPERATION AND PREVENTIVE MEASURES THEREOF
|更新时间:2025-09-28
|
CAUSE ANALYSIS OF FIRE-RESISTANT OIL'S RESISTIVITY SURPASSING SET STANDARD IN OPERATION AND PREVENTIVE MEASURES THEREOF
Thermal Power GenerationVol. 39, Issue 9, Pages: 92-94(2010)
作者机构:
河北省电力研究院
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2010
稿件说明:
移动端阅览
MA Huifang, JIA Wenju, ZHANG Liyan, et al. CAUSE ANALYSIS OF FIRE-RESISTANT OIL'S RESISTIVITY SURPASSING SET STANDARD IN OPERATION AND PREVENTIVE MEASURES THEREOF[J]. Thermal power generation, 2010, 39(9): 92-94.
DOI:
MA Huifang, JIA Wenju, ZHANG Liyan, et al. CAUSE ANALYSIS OF FIRE-RESISTANT OIL'S RESISTIVITY SURPASSING SET STANDARD IN OPERATION AND PREVENTIVE MEASURES THEREOF[J]. Thermal power generation, 2010, 39(9): 92-94.DOI:
CAUSE ANALYSIS OF FIRE-RESISTANT OIL'S RESISTIVITY SURPASSING SET STANDARD IN OPERATION AND PREVENTIVE MEASURES THEREOF
20% of turbo-generator sets have problem of fire-resistant oil's resistivity surpassing standard in operation.Based on test study in many years
the main causes of resistivity surpassing set standard have been pointed out as follows:(1)unstrict supervision in buying new fire-resistant oil;(2)the fire-resistant oil being polluted by polarized matters;(3)oil temperature in operation was not properly controlled
or partial overtemperature points existing in the system;(4)high water content in the fire-resistant oil.For this
the methods for solving said problems and corresponding countermeasures have been put forward.