您当前的位置:
首页 >
文章列表页 >
ANALYSIS OF CRACKING IN BUTT WELD-JOINTS BETWEEN THE LARGE DIAMETER THICK-WALLED THREE-WAY VALVE AND THE CONNECTING PIPE
更新时间:2025-09-28
    • ANALYSIS OF CRACKING IN BUTT WELD-JOINTS BETWEEN THE LARGE DIAMETER THICK-WALLED THREE-WAY VALVE AND THE CONNECTING PIPE

    • Thermal Power Generation   Vol. 39, Issue 6, Pages: 73-75(2010)
    • CLC: TG441.7
    • Published:2010

    移动端阅览

  • ZHAO Huichuan1, LI Xiaodong2, ZHU Xinzhao2, et al. ANALYSIS OF CRACKING IN BUTT WELD-JOINTS BETWEEN THE LARGE DIAMETER THICK-WALLED THREE-WAY VALVE AND THE CONNECTING PIPE[J]. Thermal power generation, 2010, 39(6): 73-75. DOI:

  •  
  •  

0

Views

145

下载量

8

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

CAUSE ANALYSIS OF WELD SEAM CRACKING ON THERMOCOUPLE SLEEVES USED FOR MAIN STEAM PIPELINE
ANALYSIS AND REPAIR OF CRACKS IN SOCKET WELD JOINT ON DEARATOR'S HEAD
APPLICATION OF T23 STEEL IN LARGE-SCALE COVENTIONAL UTILITY BOIlERS
CONTROL OF WELDING DEFORMATION ON STAINLESS STEEL PIPELINES
CAUSE ANALYSIS OF CRACKS OCCURRED IN ANGLE-WELDING SEAM ON INLET HEADER OF LOW-TEMPERATURE SUPERHEATER

Related Author

XU Jiang-xiao
SONG Li
CHANG Jian-bingHenan Electric Power Testing & Research Institute
YAO Bingyin1
LI Taijiang1
KANG Yujun1
WANG Caixia1
WANG Xianchun2

Related Institution

Henan Electric Power Test and Research Institute
Xi'an Thermal Power Research Institute Co., Ltd
China Resources Power Hubei Co., Ltd
Huaneng Changxing Power Plant
Wuhan Boiler Co., Ltd., Wuhan Boiler Co., Ltd., Wuhan Boiler Co., Ltd., Wuhan Boiler Co., Ltd., Hubei Wuhan 430070, Hubei Wuhan 430070, Hubei Wuhan 430070
0