STUDY ON INFLUENCE OF BACTERICIDE IN CIRCULATING WATER UPON THE REVERSE-OSMOSIS MEMBRANE
|更新时间:2025-09-28
|
STUDY ON INFLUENCE OF BACTERICIDE IN CIRCULATING WATER UPON THE REVERSE-OSMOSIS MEMBRANE
Thermal Power GenerationVol. 39, Issue 6, Pages: 29-33(2010)
作者机构:
1. 西安热工研究院有限公司
2. 华能上安电厂
3. 华能沁北发电有限责任公司
4. 西安市特种设备检验检测院
作者简介:
基金信息:
DOI:
CLC:TM621.8
Published:2010
稿件说明:
移动端阅览
TIAN Li1, HUANG Shanfeng1, LUO Jianghe1, et al. STUDY ON INFLUENCE OF BACTERICIDE IN CIRCULATING WATER UPON THE REVERSE-OSMOSIS MEMBRANE[J]. Thermal power generation, 2010, 39(6): 29-33.
DOI:
TIAN Li1, HUANG Shanfeng1, LUO Jianghe1, et al. STUDY ON INFLUENCE OF BACTERICIDE IN CIRCULATING WATER UPON THE REVERSE-OSMOSIS MEMBRANE[J]. Thermal power generation, 2010, 39(6): 29-33.DOI:
STUDY ON INFLUENCE OF BACTERICIDE IN CIRCULATING WATER UPON THE REVERSE-OSMOSIS MEMBRANE
摘要
根据华能上安电厂循环水水质和处理技术特点
设计了反渗透模拟装置
选用多种杀菌剂进行静态浸泡试验和动态模拟试验。在进水中含有不同杀菌剂情况下
对反渗透模拟装置的回收率及脱盐率等进行分析研究
系统地评价不同杀菌剂对反渗透膜性能的影响。研究结果表明
所研制的绿色杀菌剂对于采用反渗透脱盐技术处理循环水排污水的电厂较为适用
它不仅对循环水中的细菌有很好的杀灭作用
而且不会对反渗透膜产生影响;优氯净和1227杀菌剂均不适于此类电厂使用。
Abstract
Based on the circulating water quality and the treatment technology features in Huaneng Shang'an Power Plant
a simulation facility of reverse-osmosis(RO) has been designed
the static soak test and dynamic imitation test being carried out by using many kinds of bacteriside.Under condition of different bactericides containing in the inlet water
the recovery rate and desalination rate etc.of said simulation facility of reverse-osmosis have been analysed and studied
the influence of different bactericaides upon the performance of reverse-osmosis membrane being systematically evaluated.Results of study show that the developed green bactericide is suitable to power plants using RO desalting equipment to treat the blowdown circulating water
it not only can kill the bacteria in circulating water
but also can't affect the RO membrane;the bactericides
such as DCCNa and benzulconium chloride can't be used in this kind of power plant.