TECHNICAL AND ECONOMICAL ANALYSIS OF INDIRECT AIR-COOLED SYSTEM AND DIRECT AIR-COOLE SYSTEM
|更新时间:2025-09-28
|
TECHNICAL AND ECONOMICAL ANALYSIS OF INDIRECT AIR-COOLED SYSTEM AND DIRECT AIR-COOLE SYSTEM
Thermal Power GenerationVol. 39, Issue 8, Pages: 1-3(2010)
作者机构:
1. 北方联合电力有限责任公司
2. 西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2010
稿件说明:
移动端阅览
WANG Xinyu1, SHI Jianliang1, LI Guobao1, et al. TECHNICAL AND ECONOMICAL ANALYSIS OF INDIRECT AIR-COOLED SYSTEM AND DIRECT AIR-COOLE SYSTEM[J]. Thermal power generation, 2010, 39(8): 1-3.
DOI:
WANG Xinyu1, SHI Jianliang1, LI Guobao1, et al. TECHNICAL AND ECONOMICAL ANALYSIS OF INDIRECT AIR-COOLED SYSTEM AND DIRECT AIR-COOLE SYSTEM[J]. Thermal power generation, 2010, 39(8): 1-3.DOI:
TECHNICAL AND ECONOMICAL ANALYSIS OF INDIRECT AIR-COOLED SYSTEM AND DIRECT AIR-COOLE SYSTEM
摘要
介绍了北方地区发电机组空冷技术的应用情况。通过比较直接空冷和间接空冷的技术特点和投资分析
得出间接空冷系统在运行维护和技术经济性上有着较多优势
如机组运行稳定性及夏季运行安全性均较好
基本无噪音
容易清洗等。采用国产化大型间接空冷系统可提高发电厂运行的经济性。
Abstract
The situation of using air-cooled technology for power-generating units in northern area of China in recent years has been presented.Through comparison and analysis of technical features and captital investment of direct-cooled technology with indirect air-cooled technology
it is believed that the indirect air-cooled technology has more advantages in operation and maintenance
as well as in technical and economical aspects
such as the stability in operation of untis and safety in operation during summer season all are better
basically without noise
and easily to be cleaned
etc.adoption of home-made large-scale indirect air cooled system can enhance the economic efficiency in operation of power plants.
STUDY ON SPRAY HUMIDIFICATION AND TEMPERATURE REDUCTION METHOD FOR ENHANCING OUTPUT CAPACITY OF DIRECT AIR-COOLED UNITS
CALCULATION AND ANALYSIS OF CHARACTERISTICS UNDER OFF-DESIGN CONDITION OF DIRECT AIR COOLING SYSTEM FOR AIR COOLING UNITS
IMPROVEMENT OF THE CONTROL SYSTEM IN AIR-COOLED ISLAND FOR 600MW UNIT IN HUANENG TONGCHUAN POWER PLANT
OPTIMIZATION OF THE CONTROL SYSTEM IN AIR-COOLED ISLAND OF 600 MW DIRECT AIR-COOLED UNITS
INFLUENCE OF THERMAL RESISTANCE DUE TO FOULING OCCURRED IN RADIATORS'TUBEBANDLE OF THE AIR-COOLED CONDENSOR UPON THERMAL ECONOMIC EFFICINECY OF 600 MW DIRECT AIR-COOLED UNIT
Related Author
LI Yu-hui North China Electric Power University
ZHAO Wen-sheng
LIU Yang
WANG Song-ling
PENG Na Xi'an Thermal Power Research Institute Co Ltd
CHEN Sheng-li
ZHU Bao-tian
LI Gao-chao
Related Institution
North China Electric Power University
Dalat Power Plant
Siemens Power Plant Automation Co., Ltd
Shandong Electric Power Engineering Consulting Institute